Brand:Ainuo
Description:Sigle-phase/Up to 7 functions Double load for paralleled testing; 7 functions in 1 electrical safety and properties’ test; double channel display together; electric ARC, load open-circuit and short-circuit test function. Applicable to such small home appliances high-speed product lines. Technical characteristics: ◆ Compliant with GB4706.1-2005, IEC60335-1:2004, UL60335-1:2002, GB4943.1-2001, standard requirements. ◆ Three phase,single phase load compatible; Three phase rated load capacity 20kVA, can custom 60kVA. ◆ Seven functions into one device: ground bond, insulation resistance, AC hipot, DC hipot, leakage current, power test and low voltage start test. ◆ 15-group / 8-step test condition, intelligent judgment, auto compensation, auto protection;High speed test, the fastest speed can be 0.5s. ◆ Voltage ramp-up and ramp-down, discharge function;Dynamic and static leakage current, hipot test. ◆ Auto compensation, auto protection, auto memory, auto judgment, voice and light alarm. ◆ Serial communication, print, foot pedal interface, outer alarm light, PLC, network card interface. ◆ For safety test, the precision is 2%, for power test, the precision is 5%;For DUT, can support both grounding and suspending. ◆ Function preview, single screen setting, no need flip, simple operation. ◆ Support both 50Hz and 60Hz frequency, Chinese and English operation interface.
Origin:China
Model:AN9651TH(F)
FOB:perUnit/Units800--5000USD
Supply Ablility:100Unit/Units
Supply Time:Month
Packaging Details:Wooden case
Product detail:
Model |
AN9651TH (F)(Three Phase/single phase7 in1) |
Ground Bond Test |
|
Empty Load Output Voltage |
<12V |
Output Current Setting Range |
AC3A~30A 50Hz/60Hz,1A/step |
Output Current Setting Accuracy |
±(2% of setting+0.2A) |
Upper Limit of Resistance |
3A≤output current≤10A, 10~600mΩ; 10A |
Ground Bond Resolution/ Measurement Range/ Accuracy |
1mΩ, 10~600mΩ, ±(2% of reading +2mΩ) |
Compensation Resistance Measurement Range/Accuracy |
0~200mΩ 1mΩ |
Test Time Setting Range |
0.5~999.9s 0.1s/step |
Insulation Resistance Test |
|
Rated Output Load/Current |
1VA (1000V/1mA) 1mA |
Output Voltage Range/Adjustable |
DC:500V/1000V <1% (Empty load to full load) |
Output Voltage Ripple |
Pure resistance load, 1000V/1mA, <3% |
Insulation Resistance Range |
1.0~2000MΩ |
Insulation Resistance Lower Limit Setting Range/ Resolution |
1.0~99.9 MΩ, 0.1MΩ/step, 100~2000 MΩ 1 MΩ/step |
Insulation Resistance Accuracy |
1~200 MΩ: ±(2% of reading+2counts) , 200~2000 MΩ: ±(5% of reading+5counts) |
Ramp-up Time Range/Resolution |
0.1~999.9s 0.1s |
Delay Judgment Time |
0.3~10.0s (Count from ramp-up ) |
Test Time Setting Range |
0.5~999.9s 0.1s/step |
AC Hipot Test |
|
Rated Output Load |
500VA (AC:5000V/100mA) |
Output Voltage Range /Frequency/Adjustable Rate |
500~5000V, 50Hz/60Hz, <2%(Empty load to full load) |
Output Voltage Setting Range/Accuracy |
Cold state AC:500~5000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V) |
Leakage Current Preset Alarm |
Upper limit: 0.10~99.99mA; Lower limit: 0.00~99.99mA , 0.01mA/step |
Compensation Current Setting Range/ Resolution |
0.00 ~5.00mA, 0.01mA |
Output Initial Voltage Range |
(0%~99%) of test voltage, from 0V to initial voltage need 200ms |
Leakage Current Measurement Range/Resolution/Accuracy |
0.10~99.99 mA, 0.01mA, ±(2% of reading +2counts) |
Test Time/Ramp-Up/Ramp-Down |
0.5~999.9s, 0.1~999.9s, 0.0~999.9s(After test pass) |
DC Hipot Test |
|
Rated Output Load |
60VA (AC:6000V/10mA) |
Output Voltage Range /Frequency/Adjustable Rate |
500~6000V, <2%(Empty load to full load) |
Output Voltage Setting Range/Accuracy |
Cold state AC:500~6000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V) |
Leakage Current Preset Alarm |
Upper limit: 50~9999μA; Lower limit: 0~9999μA , 1μA |
Compensation Current Setting Range/ Resolution |
0 ~5000μA, 1μA |
Output Initial Voltage Range |
(0~99%) of test voltage, from 0V to initial voltage need 200ms |
Leakage Current Measurement Range/Resolution/Accuracy |
50~9999μA , 1μA, ±(2% of reading +2counts) |
Test Time/Ramp-Up/Ramp-Down |
0.5~999.9s, 0.1~999.9s, 0.3~10.0s(Count from ramp-up) |
Leakage Current Test |
|
Output Voltage Range |
1.06 times of input voltage (output by isolated transformer) |
Leakage Current Range/Resolution |
Upper limit: 50~9999μA 1μA |
Compensation Current Setting Range/ Resolution |
0~500μA 1μA |
Test Time Range/Resolution |
1.0 ~999.9s 0.1s |
Leakage Type |
dynamic, static |
Three Phase Dynamic Mode |
A mode: ABC-AB-BC-CA (standard) |
Output Voltage Measurement Range/Accuracy |
AC 50~500.0V 0.1V, ±(0.5% of reading+2counts) |
Leakage Current Measurement Range/Accuracy |
50~9999μA 1μA |
Leakage Current Accuracy |
50.0~2000μA is ±(5% of reading);2000μA or above is ±(2.5% of reading) |
Leakage Power |
6kVA ,isolated transformer capacity is designed according to the rated voltage 220V |
Time Setting Range |
1~300s |
Measurement Mode |
dynamic, static |
Power Test |
|
Output Voltage Range |
1.00 times of input voltage (output by isolated transformer) |
Power Setting Range/Resolution |
Upper limit, Single phase:20~6000W Three phase:60~20000W |
Test Time Range/Resolution |
0.5 ~999.9s 0.1s |
Voltage Measurement Range and Accuracy |
AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts) |
Current Measurement Range and Accuracy |
AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts) |
Active Power Measurement Range and Accuracy |
20.0~999.9W; 1.000~9.999kW; 10.00~20.00kW |
Power Factor Range and Accuracy |
0.100~1.000, ±(2% of reading +2counts) |
Low Voltage Start Test |
|
Output Voltage Range |
0.85 times of input voltage (output by isolated transformer) |
Test Time Range/Resolution |
0.5 ~999.9s 0.1s |
Current Setting Range/Resolution |
Upper limit: 0.30 ~30.00A Lower limit: 0.00 ~30.00A0.01A |
Voltage Measurement Range and Accuracy |
AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts) |
Current Measurement Range and Accuracy |
AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts) |
Display Mode |
10.4 Inch, 640×480, TFT LCD display |
Isolated Transformer Capacity |
Three Phase:20kVA, Single Phase: 6kVA |
Over Current Protection |
Power, Start, Leakage Current, Phase Current35A, over 5s protection |
DUT Type Setting |
Single Phase, Three phase Three line, Three phase Four line |
Grounding Mode |
Load Grounding, Load Floating |
DUT Error Processing |
Voice and light alarm |
Outer Alarm Light |
Red alarm light |
PLC Output Interface |
Each test function have one |
Interface Function |
RS232, Outer Printer, Remote |
Optional Interface |
RS485, GPIB, Internet Card, Inner Printer |
Remote control Interface |
Foot Pedal, three-color alarm light(on-off signal output, PRINTER, 97 COM interface, Mini-Printer function optional) |
Test Group |
15 groups, 8 steps / group |
Buzzer Alarm Voice |
Can turn on ,Can cut |