Safety tester AN9651F(F)

Click for original picture
Fob Price: Discuss personally 
Supply Ability: 100
Payment Terms: delivery withindays since payment
Location: China Shandong
  Ada    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:Ainuo

Description:Main features * Comply with CCC,IEC EN,VED,BS,UL,JIS standard requiements. * Latest international standard:500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A *6 in 1:AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start. Standby power consumption is optional for AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2% * Simple operation:LED backlit screen display.menu operation,Chiense/English langues,socket test fixture. * Flexible configuration:Built in isolated transformer,AC frequency conversion power supply,frequency conversion power supply and industrial PC combiantion

Origin:China

Model:AN9651F(F)

FOB:perUnit/Units500--5000USD

Payment Terms:Other

Supply Ablility:100Unit/Units

Supply Time:Month

Packaging Details:Wooden case

Product detail: 

AC Hipot test

 

Booster rated output capacity

500VA(5000V/100mA)

 

Booster maximum short-circuit current

>200mA

 

Output waveform

Sine wave, <3%(pure resistance,5000V/1mA),<3%(From empty load to full load)

 
 

Output voltage setting

Range

500~5000V

 

Resolution

5V

 

Accuracy

±(3%×setting+10V)

 

Frequency setting

Range

50Hz/60Hz

 

Accuracy

±0.1%×setting

 

Alarming limits setting

Current upper-limit

0.10~99.99mA

 

Current lower-limit

0.00~10.00mA

 

Compensation current setting

Range

0.00~10.00mA, automatic testing, compensation can be set to ON/OFF

 

Time setting

Range

1~999s

 

Ramp up time range

1~100s

 

Accuracy

±(0.1%×setting+1count)

 

Breakdown current alarm

Range

0.10~99.99mA

 

Accuracy

±(3%×reading+3counts)

 

Insulation Resistance test

 

Rated output capacity

2VA(1000V/2mA)

 

Output voltage regulation

<3%(From no load to full load)

 

Output voltage ripple

<1%

 

Output voltage setting

Range

DC 500Vor1000V

 

Accuracy

±(3%×setting+3counts)

 

Alarming limits setting

Resistance upper-limit range

0.0~99.9 MΩ,100~2000MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit)

 

Resistance lower-limit range

0.3~99.9 MΩ, 100~2000MΩ

 

Time setting

Range

1~999s

 

Accuracy

±(0.1%×setting+1count)

 

Insulation resistance measurement

Range

0.0~99.9 MΩ, 100~2000 MΩ

 

Accuracy

≤200MΩ: ±(3%×reading+3counts)

 

200MΩ:±(8%×reading+8counts)

 

Ground Bond Resistance test

 

No load output voltage

<12V

 

Output current setting

Range

3~30A

 

Accuracy

±(3%×setting+0.2A)

 

Current range instruction

Optional: 3 ~ 64A test current

 

Current frequency setting

Range

Sine waveform 50Hz/60Hz

 

Accuracy

±0.1%×setting

 

Test time setting

Range

1~999s

 

Accuracy

±(0.1%×setting+1count)

 

Result display mode

Ground resistance or voltage

 

Ground resistance display mode

 

Alarming limits setting

Resistance upper-limit range

3A≤output current≤10A:10~600 mΩ

 
 
 

Resistance lower-limit range

0~100 mΩ

 

Compensation resistance setting

Range

0~200 mΩ, automatic testing, compensation can be set to ON/OFF

 

Ground bond resistance measurement

Range

10~600 mΩ

 

Accuracy

±(3%×reading+ 5counts)

 

Ground voltage display mode

 

Alarming limits setting

Voltage upper-limit range

30~7500 mV

 

Voltage lower-limit range

0~3000 mV

 

Compensation voltage setting

Range

0~1000 mV, automatic testing, compensation can be set to ON/OFF

 

Ground bond resistance measurement

Range

10~7500 mV

 

Accuracy

±(3%×reading+ 50mV)

 

Leakage Current test

 

Leakage current test type setting

Single phase load, static/dynamic leakage current

 

MD network selection

Standard IEC 60335-1 figure 4 network;other test network optional

 

Alarming limits Setting

Current upper-limit range

0.050~9.999mA

 

Current lower-limit range

0.000~5.000mA

 

Leakage current compensation setting

Range

0.000~1.000mA, automatic testing, compensation can be set to ON/OFF

 

Time test setting

Range

1~999s

 

Accuracy

±(0.1%×setting+1count)

 

Leakage current measurement

Range

0.050~9.999mA

 

accuracy

DC~10kHz:±(3%×reading+0.010mA)

 
 

Output voltage measurement

Range

60~280V(phase voltage)

 

accuracy

±(0.5%×reading+2counts)

 

Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F)

 

Alarming limits setting

Power upper-limit range

6~6000W

 

Power lower-limit range

0~6000W

 

Test time setting

Range

1~999s

 

Accuracy

±(0.1%×setting+1count)

 

Voltage measurement

Range

60~280V(phase voltage)

 

Accuracy

±(0.5%×reading+2counts)

 

Current measurement

Range

0.030~3.999A, 4.00~25.00A

 

Accuracy

±(0.5%×reading+2counts)

 

Active power measurement

Range

30.0~199.9W:±(0.5%×reading+5W)

 

Accuracy

200~6000W(or2000W):±(0.5%×reading+30W)

 

 
more..Other products from this supplier

[ ProductsSearch ]  [ [ Print ]  [ Close ]


Copyright © 2004 ChinaAseanTrade.com All rights reserved
中国-东盟自由贸易网版权所有@2004 沪lCP证05013507号

沪公网安备 31010102002066号