3 phase modular UPS 50-800kva

Click for original picture
Fob Price: Discuss personally 
Port: Tianjin
Supply Ability: 28
Payment Terms: delivery withindays since payment
Location: China Hebei
  Vivian    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:Sicon

Description:Basic Information Truly Modular UPS Full UPS functioned UPS Module Choice of UPS Module (10kVA, 25kVA, 50kVA) result in Rational Redundancy Modular, hot-swappable, field-replaceable STS, Monitor, UPS module Scalable from 10kVA to 800kVA. Parallel-capable up to 3200kVA. 

Origin:China

Model:CMS500/50

MOQ:1Unit/Units

FOB:perCase/Cases3580--10000USD

Port:Tianjin

Payment Terms:T/T

Supply Ablility:28Case/Cases

Delivery Time:2017-12-09

Packaging Details:wooden case

Product detail:

 Basic Information

Truly Modular UPS

Full UPS functioned UPS Module

Choice of UPS Module (10kVA, 25kVA, 50kVA) result in Rational Redundancy

Modular, hot-swappable, field-replaceable STS, Monitor, UPS module

Scalable from 10kVA to 800kVA. Parallel-capable up to 3200kVA. 

Overview

CMS UPS units are non-isolated, industrial level, green UPS, adopting advanced modular power protection concept. CMS Modular architecture can scale power as demand grows or as higher levels of availability are required. CMS UPS is industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments.

Feature

· Rational redundant structure

· UPS module: 10 kVA, 25 kVA, 50 kVA; System: 50kVA, 100 kVA, 150kVA, 250 kVA, 350 kVA,    500 kVA, 800 kVA.

· Great performance index: overall efficiency ≥ 95%(AC-AC), inverter efficiency ≥ 98%(DC-AC), THDI ≤ 3%, and input PF ≥ 0.99

· N+X module-level redundancy UPS System

· Multi-level decentralized control technology and Master-slave synchronization in sequency control which result in eliminate system failure bottleneck

· Each module automatically even shares the input and output current, all UPS modules share batteries

· Battery Management Function:

· Battery discharge management, auto-transfer between floating and even charging, temperature compensation

· Space-saving high density design, Rack-based for agility and aesthetics

· Monitor Function

· C/S-Oriented Architecture SICON Software which is available to monitor multiple UPS up   to 600 sets; B/S-Oriented Architecture which is available to check via IE

· Standard configuration

· Manual maintenance bypass, SPD(Class C), RS232, RS485/RS422 Communication ports,       Remote monitor software, day contacts

· Optional configuration

· EPO, Input/output Transformer, Battery Bank, IPDS(Intelligent Power Distribution System)

System model

CMS-50/10

CMS-100/10

CMS-150/25

CMS-250/25

CMS-350/50

CMS-500/50

CMS-800/50

Maximum power

50 kVA

100kVA

150 kVA

250 kVA

350 kVA

500kVA

800KVA

Power module model

               10 kVA

           25KVA

                     50KVA

Mains Input

Input mode

3-phase +N +E, 1-phase +N +E

Input voltage

380V/220V±20%, 400V/230V±20%, 415V/240V±20%

Input frequency

50Hz±10%, 60Hz±10%

Power woke-in (Sec.)

60sec

THDI (%)

<3%

Input PF

≥0.99

Bypass Input

Input voltage

380V/220V±20%, 400V/230V±20%, 415V/240V±20%

Input frequency

50 Hz, 60 Hz

Range of Frequency Synchro

50 Hz±4%, 60 Hz±4%

DC Input

Rated Input voltage

±384VDC

Input voltage tolerance

±345V~±440V DC

Battery charging

Charging current limited

yes

Charging ability

10 hours (2 hours back up)

Stability of charging voltage

±1%

AC output

UPS power factor

0.9

Output voltage

380V/220V AC, 400V/230V AC, 415V/240V AC

Output frequency

±4%;±0.2% (battery supply)

Output voltage stability

±1%

Output voltage recovering time

<20ms(load 0~100% change)

Overload ability

Operate 10mins with 125% load

Transfer from mains to battery supply

0ms

Transfer from bypass to inverter supply

<1ms

Peak factor

'3:1

Waveform distortion

≤1% ( linear load ),  ≤3%( non-linear load )

Overall efficiency

≥95% (AC~AC),  ≥98% (DC~AC)

Load share precision

≤5%

Operation environment

Ambient temperature

-25℃~60℃

Operating temperature

-5℃~40℃

Maximum operation altitude

≤1500m

Relative humidity

≤95% non-cadency

Protection degree

IP30

Cooling

Air cooling

Applicable safety standards

EN62040-1-1:2003     IEC60950-1:2001

Electromagnetic compatibility

EN62040-2:2006

Acoustic noise

≤55DB

Others

Cabinet

Standard 19 inch cabinet

Monitor management system

UPSupervisor

Interface

RS232, RS485 and 8 try contact, TCP/IP adapter, SNMP(optional)

Display

Touch LCD/LED Screen

Weight(kg)

150

200

200

260

400

500

700

 

WHY CHOOSE SICON?

Corporate URL: www.sicon-emi.com  

Sicon Modular UPS

Full range modular UPS 6-3200kVA, 14 years experience, No.1 market share in China

 

Contact Sicon:
Corporate URL:  www.sicon-emi.com 

Email:enquiry@scupower.com
Tel: +86 311 85903762

 

 
more..Other products from this supplier

[ ProductsSearch ]  [ [ Print ]  [ Close ]


Copyright © 2004 ChinaAseanTrade.com All rights reserved
中国-东盟自由贸易网版权所有@2004 沪lCP证05013507号

沪公网安备 31010102002066号