Professional abc cable manufacturer

Click for original picture
Fob Price: 1.00 USD/ 
MOQ: 500  
Payment Terms: delivery withindays since payment
Location: China
  Ms. Cathy Li    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:aa

Product detail:

 

Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE/PVC insulation, Aluminum Conductor

 

Product D 

1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex
Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

 

 

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

ABC cable

16 mm 2 * 2C

( AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

16 mm 2 * 4C

3*(AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

25 mm 2 * 2C

( AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

25 mm 2 * 4C

3*(AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

35 mm 2 * 2C

( AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

35 mm 2 * 4C

3*(AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

50 mm 2 * 2C

( AL19/1.78+PE O.D.11.7) + AL19/1.78

50 mm 2 * 4C

3*(AL19/1.78+PE O.D.11.7) + AL19/1.78

70 mm 2 * 2C

( AL19/2.12+PE O.D.13.5) + AL19/2.12

70 mm 2 * 4C

3*(AL19/2.12+PE O.D.13.5) + AL19/2.12

95 mm 2 * 2C

( AL19/2.50+PE O.D.15.8) + AL19/2.50

95 mm 2 * 4C

3*(AL19/2.50+PE O.D.15.8) + AL19/2.50

 

All above can do as every different standards OR as your special request

 

 
more..Other products from this supplier

[ ProductsSearch ]  [ [ Print ]  [ Close ]


Copyright © 2004 ChinaAseanTrade.com All rights reserved
中国-东盟自由贸易网版权所有@2004 沪lCP证05013507号

沪公网安备 31010102002066号