Brand:aa
Product detail:
CAP 1kw-6kw off grid INVERTER
1. Features
user selectable for accepting wider input voltage .
Full automatic and silent operation.
Rack tower design.
High frequency design.
Available in five AC outlet configuration:NEMA,Schuko,French,India,BS 1363.
Compact size for convenient use and storage.
Built-in 8 Amp supper charger for up to 100AH battery.
Small scale and cost effective inverter for home and office appliances.
Two-steps intelligent charging control to reduce the recharging time.
2.Specification
Model No. | LW1000 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 |
Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
AC Input | ||||||
Phase & waveform | Single phase & Pure Sine Wave | |||||
Voltage | 120VAC/230VAC | |||||
Acceptable Voltage | 194-243VAC\164-243VAC(wide mode) | |||||
Line Low Transfer | 85V±4%/184(154 wide mode±4%) | |||||
Line Low Return | 95V±4%/194(164 wide mode±4%) | |||||
Line high Transfer | 135V±4%/253±4% | |||||
Line high Return | 127V±4%/243±4% | |||||
Frequency | 50Hz or 60Hz (auto sensing) | |||||
Line Low Transfer | 47Hz for 50Hz,57Hz for 60Hz | |||||
Line high Transfer | 55Hz for 50Hz,65Hz for 60Hz | |||||
Output | ||||||
Phase & waveform | Single phase & Pure Sine Wave(bypass mode sync to input) | |||||
Voltage | 120/220/230/240VAC(bypass mode sync to input) | |||||
Voltage Regulation | ±10%rms(bypass mode sync to input) | |||||
Frequency | 50Hz±0.3Hz(bypass mode sync to input) | |||||
Peak Power | 3 times of rating power | |||||
Short Circuit Protection | Yes,shutdown after 10ms | |||||
Power Factor | 0.9-1.0 | |||||
DC Input | ||||||
Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V | |||
Minimum Start Voltage | 10V for 12V,20V for 24V,40V for 48V | |||||
Low Battery Alarm | 10.5V for 12V,21V for 24V,42V for 48V | |||||
Low Battery Transfer | 10V for 12V,20V for 24V,40V for 48V | |||||
High Voltage Alarm | 16V for 12V,32V for 24V,64V for 48V | |||||
Max Charging Current | 35A/70A | |||||
Over Charge Voltage | 15.7V for 12V,31.4V for 24V,62.8V for 48V | |||||
Transfer Efficiency | ||||||
Line Mode | more than 95% | |||||
Battery Mode | more than 88% | |||||
power saver | Available when the load is less than 25 Watts | |||||
Indicators | ||||||
7-LED Display | From the right to the left,LED1 line mode (green lighting),LED2 inverter mode | |||||
(green lighting),LED3 charging mode(yellow lighting),LED4 Fully charged | ||||||
(green lighting),LED5 over heat shutdown(red lighting),LED6 Overloaded | ||||||
shutdown(red lighting),LED7 Saving Mode(green lighting) | ||||||
3-LED Display | Charging Mode(green lighting),inverter mode(green lighting), Alarm(red lighting) | |||||
Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is | |||||
turning the inverter off. | ||||||
Audible Alarm | Sounding when the heatsink's tem is over 105°C and shutdown after 30 seconds. | |||||
Protections | low battery,over charging,over temp,over load | |||||
Communications | RS-232/USB(custom-made) | |||||
Enviromental | ||||||
Operating Environment | 0-40°C,0-90%RH(non-condensing) | |||||
Audible Noise | less than 60dB | |||||
Physical |
|
|
|
|
|
|
Net Weight(KG) | 20KG | 20KG | 26KG | 48KG | 48KG | 48KG |
Dimension,D X W X H(mm) | 218X179X442mm | 218X179X598mm |