Calorimeter uses
1, APEX indirect calorimeter ISO1928: 1995 called calorimeters, said domestic kcal instrument,
the main measure of coal, straw, bio-fuels and other solid amount of heat,
but also measurable heat oil and other liquids, mainly for thermal power, cement, coal, new energy and other fields.
2, APEX indirect calorimeter ISO1928: 1995 widely used. Coal mines, power plants and other areas of energy supply,
energy quality to be assessed. Which determines the price.
3, APEX indirect calorimeter ISO1928: 1995 widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.
4, APEX indirect calorimeter ISO1928: 1995 according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.
5,APEX indirect calorimeter ISO1928: 1995 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.
APEX indirect calorimeter ISO1928: 1995 advantage
1, APEX indirect calorimeter ISO1928: 1995 has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.
2, fast APEX APEX indirect calorimeter ISO1928: 1995 is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .
3 , accurate APEX indirect calorimeter ISO1928: 1995 according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.
4 , the history APEX founded 30 years long history , strong, development,
and manufacturing APEX indirect calorimeter ISO1928: 1995 also has 20 years of history.
5 , maturity APEX indirect calorimeter ISO1928: 1995 products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.
6 , the operation APEX indirect calorimeter ISO1928: 1995 by our many years of continuous improvement.
Has a higher degree of customer premise practical as possible
within the scope of our technical strength . Increased automation better .
Operation more simple device . Equipment for laboratory technicians is increasing demand is low.
In the future. We hope. Anyone may not be trained to use our equipment .
We have now done . Automatic water, automatic drainage ,
automatic printing , automatic calculation , automatic constant temperature inside and outside the barrel ,
automatic ignition, automatic temperature compensation, and other functions.
7 , the service APEX services are possible to meet more customer needs.
Products , customization, training , and other services that we will try to do our best.
And . Now use the Internet to build provides remote maintenance, remote training the ability to teach .
For the supply of goods services. increased from merely providing
maritime shipping services. Changes can now be based on customer demand ,
air or express delivery services. So that your home can directly get the desired device
8 , the performance APEX indirect calorimeter ISO1928: 1995 stable performance, can be a long run .
We conducted two ways of stabilization method .
1 is a temperature correction using the software . The temperature of the outer cylinder 2 additional cooling means
1, APEX indirect calorimeter ISO1928: 1995 structure
APEX indirect calorimeter ISO1928: 1995 shape with floor cabinet structure , the top left is an elastic closure
pressure openable cover ( commonly known as the cover ) and so on. Blenders
inner cylinder , the inner cylinder and the ignition temperature probe center electrode are
installed in the cover. 2, APEX indirect calorimeter ISO1928: 1995 function
(1), APEX indirect calorimeter ISO1928: 1995 using advanced single-chip microcomputer system ,
complete with instrumentation and unique water system
and the amount of thermal systems to auto-complete :
inner tube replacement and quantitative water cooling : automatic mixing , automatic ignition ,
data acquisition and processing, data storage , instrument status display , audible alert or alarm ,
printouts various reports .
(2), APEX indirect calorimeter ISO1928: 1995 AD imported high-grade large-scale integrated devices ,
to achieve dual high-speed , high-precision temperature measurement makes the operation easier
and more accurate measurements .
(3), APEX indirect calorimeter ISO1928: 1995 using large size graphic LCD display to display the various states of the instrument ,
data and graphics. Chinese menu interface , intuitive , friendly
and easy to use. 3,APEX indirect calorimeter ISO1928: 1995 specifications
( 1 ) , the heat capacity ( water equivalent ) : about 10500 J / K ( co 2500cal / K)
( 2 ) , oxygen bomb : Working pressure ( filling oxygen ) :2.8-3 .0 Mpa Max 3.2Mpa
Pressure test ( hydrostatic ): 20Mpa
Volumetric : 300mL
Weight : 2.5KS
Dimensions : Φ86mm × l81mm
( 3 ) , the inner barrel of water : about 2100mL
( 4 ) , the outer sleeve and water storage cartridges Capacity: Approximately 20L
( 5 ) , temperature measurement system :
Let the inner tube ( the probe in the roof ) and the outer sleeve ( probe with flange mounted on the outer wall of the sleeve ) ends ,
the corresponding screen is displayed as : IT or OT:
Display range : 0-65.535 ℃
Display resolution : 0.001 ℃
( 6 ) , heat capacity Repeatability: better than 0.1%
4, style="color:#0000cd;">APEX indirect calorimeter ISO1928: 1995 Application Operation
APEX indirect calorimeter ISO1928: 1995 calorimeter high degree of automation . Just a few steps to get the desired test results . Is very simple.
( 1 ) : Samples were weighed on a balance
( 2 ) : Weigh the sample into a bomb inside , and use our gift of automatic oxygenation apparatus filled with oxygen.
( 3 ) : the bomb into the calorimeter . And the sample weight and other data input calorimeter .
( 4 ) : Click : Start
( 5 ) : Waiting
( 6 ) : Wait......
( 7 ) OK. Results are automatically begin printing
1, APEX indirect calorimeter ISO1928: 1995 calorimeter characteristics
( 1 ) gay than the international market price of energy calorimeter low
( 2 ) than the international market prices of products with high performance .
Strong advanced degree .
( 3 ) long life , one year warranty . Repair rate is less than 2% a year
( 4 ) can be customized in different languages ,
so that he can use around the world
( 5 ) the outer cylinder storage capacity, better thermal stability
( 6 ) on the use of ambient temperature requirements relaxed
( 7 ) can be modified voltage and frequency
2, APEX indirect calorimeter ISO1928: 1995 product characteristics value to customers
(1) calorimeter coal ratio for brick inside to provide accurate data ,
improve production quality bricks . Brick customers improve economic efficiency.
(2) The power plant customers calorimeter approach can accurately identify the total number of coal energy .
Grasp the cost of raw materials . Avoid the case of the data is not clear material cause economic losses.
One can not accurately detect plant raw calories . Day economic losses can buy dozens of the calorimeter .
(3) coke industry . Coke customized production, unable to leave
the accurate detection of heat . Will lead to coke quality fluctuated .