Brand:aa
Product detail:
Calorimeter uses
1, APEX calorimeter lab petroleum pipeline called calorimeters, said domestic kcal instrument,
the main measure of coal, straw, bio-fuels and other solid amount of heat,
but also measurable heat oil and other liquids, mainly for thermal power, cement, coal, new energy and other fields.
2, APEX calorimeter lab petroleum pipeline widely used. Coal mines, power plants and other areas of energy supply,
energy quality to be assessed. Which determines the price.
3, APEX calorimeter lab petroleum pipeline widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.
4, APEX calorimeter lab petroleum pipeline according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.
5,APEX calorimeter lab petroleum pipeline 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.
6,APEX calorimeter lab petroleum pipeline commonly used assessment fuel combustion heat
can also be used to calculate the ratio of coal bricks.
Explosives equivalent research and development.
APEX calorimeter lab petroleum pipeline advantage
1, APEX calorimeter lab petroleum pipeline has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.
2, fast APEX APEX calorimeter lab petroleum pipeline is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .
3 , accurate APEX calorimeter lab petroleum pipeline according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.
4 , the history APEX founded 30 years long history , strong, development,
and manufacturing APEX calorimeter lab petroleum pipeline also has 20 years of history.
5 , maturity APEX calorimeter lab petroleum pipeline products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.
6 , cost and operation and maintenance costs APEX calorimeter lab petroleum pipeline because low energy consumption. Operating costs are not high .
Degree of automation is superior. Greatly reduce labor and maintenance costs . During use .
Human labor cost reduction is the process of liberation . Them . We focused on our customers ,
the implementation of low-cost supply of spare parts and consumables . Reduce the cost of consumables used .
7 , the operation APEX calorimeter lab petroleum pipeline by our many years of continuous improvement.
Has a higher degree of customer premise practical as possible
within the scope of our technical strength . Increased automation better .
Operation more simple device . Equipment for laboratory technicians is increasing demand is low.
In the future. We hope. Anyone may not be trained to use our equipment .
8 , the performance APEX calorimeter lab petroleum pipeline stable performance, can be a long run .
We conducted two ways of stabilization method .
1 is a temperature correction using the software . The temperature of the outer cylinder 2 additional cooling means
1, APEX calorimeter lab petroleum pipeline structure APEX calorimeter lab petroleum pipeline shape with floor cabinet structure , the top left is an elastic closure pressure
openable cover ( commonly known as the cover ) and so on. Blenders inner cylinder , the inner cylinder and
the ignition temperature probe center electrode are installed in the cover. The right is the operation of the instrument panel LCD display and printer
panel . Let the upper front power switch : Power lead socket in the back of the upper instrument .
APEX calorimeter lab petroleum pipeline interior include: SCM system , the amount of heating systems , water systems, electrical control systems, power supplies and other accessories.
2, APEX calorimeter lab petroleum pipeline function
1, APEX calorimeter lab petroleum pipeline using advanced single-chip microcomputer system ,
complete with instrumentation and unique water system and the amount
of thermal systems to auto-complete :
inner tube replacement and quantitative water cooling :
automatic mixing , automatic ignition , data acquisition and processing, data storage ,
instrument status display , audible alert or alarm ,
printouts various reports . With a fully functional , accurate measurement, calculation fine ,
intuitive display, Chinese interface, easy operation , high durability and easy maintenance are intelligent automatic heat measuring device .
Simply install bomb lab technician manual operation , the instrument automatically completed by other processes .
2, APEX calorimeter lab petroleum pipeline AD imported high-grade large-scale integrated devices ,
to achieve dual high-speed , high-precision temperature measurement makes
the operation easier and more accurate measurements .
3, APEX calorimeter lab petroleum pipeline specifications
( 1 ) , the heat capacity ( water equivalent ) : about 10500 J / K ( co 2500cal / K)
( 2 ) , oxygen bomb :
Working pressure ( filling oxygen ) :2.8-3 .0 Mpa Max 3.2Mpa
Pressure test ( hydrostatic ): 20Mpa
Volumetric : 300mL
Weight : 2.5KS
Dimensions : Φ86mm × l81mm
( 3 ) , the inner barrel of water : about 2100mL
( 4 ) , the outer sleeve and water storage cartridges Capacity: Approximately 20L
( 5 ) , temperature measurement system :
Let the inner tube ( the probe in the roof ) and the outer sleeve ( probe with flange
mounted on the outer wall of the sleeve ) ends , the corresponding screen is displayed as : IT or OT:
Display range : 0-65.535 ℃
Display resolution : 0.001 ℃
( 6 ) , heat capacity Repeatability: better than 0.1%
4, APEX calorimeter lab petroleum pipeline Application Operation
APEX calorimeter lab petroleum pipeline calorimeter high degree of automation .
Just a few steps to get the desired test results . Is very simple. ( 1 ) : Samples were weighed on a balance
( 2 ) : Weigh the sample into a bomb inside , and use our gift of automatic
oxygenation apparatus filled with oxygen.
( 3 ) : the bomb into the calorimeter . And the sample weight and other data input calorimeter .
( 4 ) : Click : Start ( 5 ) : Waiting ( 6 ) : Wait (7): OK. Results are automatically begin printing
1, APEX calorimeter lab petroleum pipeline calorimeter characteristics
( 1 ) gay than the international market price of energy calorimeter low
( 2 ) than the international market prices of products with high performance .
Strong advanced degree .
( 3 ) long life , one year warranty . Repair rate is less than 2% a year
( 4 ) can be customized in different languages ,
so that he can use around the world
( 5 ) simple operation, high degree of automation , 5 -step to the result
( 6 ) Measurement error : better than GB
( 7 ) without adjusting the water temperature inside and
outside the cylinder automatic quantitative water , quantitative error : ± 1g
( 8 ) the outer cylinder storage capacity, better thermal stability
( 9 ) on the use of ambient temperature requirements relaxed
( 10 ) can be modified voltage and frequency
2, APEX calorimeter lab petroleum pipeline product characteristics value to customers
(1) calorimeter coal ratio for brick inside to provide accurate data ,
improve production quality bricks . Brick customers improve economic efficiency.
(2) The power plant customers calorimeter approach can accurately identify the total number of coal energy .
Grasp the cost of raw materials . Avoid the case of the data is not clear material cause economic losses.
One can not accurately detect plant raw calories . Day economic losses can buy dozens of the calorimeter .
(3) coke industry . Coke customized production, unable to leave
the accurate detection of heat . Will lead to coke quality fluctuated .