APEX oxygen bomb calorimeter flex fuel e85 new product

Click for original picture
Fob Price: 10000.00 USD/ 
MOQ: 1  
Payment Terms: delivery withindays since payment
Location: China
  Ms. yang li    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:aa

Product detail:

1, APEX oxygen bomb calorimeter flex fuel e85 called calorimeters, said domestic kcal instrument,
the main measure of coal, straw, bio-fuels and other solid amount of heat,
but also measurable heat oil and other liquids, mainly for thermal power, cement, coal, new energy and other fields.

2, APEX oxygen bomb calorimeter flex fuel e85 widely used.Which determines the price.

3, APEX oxygen bomb calorimeter flex fuel e85 widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.

4, APEX oxygen bomb calorimeter flex fuel e85 according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.

5,APEX oxygen bomb calorimeter flex fuel e85 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.

6,APEX oxygen bomb calorimeter flex fuel e85 commonly used assessment fuel combustion heat
can also be used to calculate the ratio of coal bricks.

APEX oxygen bomb calorimeter flex fuel e85 advantage

1, APEX oxygen bomb calorimeter flex fuel e85 has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.

2, fast APEX APEX oxygen bomb calorimeter flex fuel e85 is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .

3 , accurate APEX oxygen bomb calorimeter flex fuel e85 according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.

4 , maturity APEX oxygen bomb calorimeter flex fuel e85 products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.

5 , cost and operation and maintenance costs APEX oxygen bomb calorimeter flex fuel e85 because low energy consumption. Operating costs are not high .
Degree of automation is superior. Greatly reduce labor and maintenance costs . During use .
Human labor cost reduction is the process of liberation . Them . We focused on our customers ,
the implementation of low-cost supply of spare parts and consumables . Reduce the cost of consumables used .

6 , the operation APEX oxygen bomb calorimeter flex fuel e85 by our many years of continuous improvement.
Has a higher degree of customer premise practical as possible
within the scope of our technical strength . Increased automation better .
Operation more simple device . Equipment for laboratory technicians is increasing demand is low.
In the future. We hope. Anyone may not be trained to use our equipment .

We have now done . Automatic water, automatic drainage ,
automatic printing , automatic calculation , automatic constant temperature inside and outside the barrel ,
automatic ignition, automatic temperature compensation, and other functions.

7 , the service APEX services are possible to meet more customer needs.
Products , customization, training , and other services that we will try to do our best.

And . Now use the Internet to build provides remote maintenance, remote training the ability to teach .

For the supply of goods services. increased from merely providing
maritime shipping services. Changes can now be based on customer demand ,
air or express delivery services. So that your home can directly get the desired device

8 , the performance APEX oxygen bomb calorimeter flex fuel e85 stable performance, can be a long run .
We conducted two ways of stabilization method .
1 is a temperature correction using the software . The temperature of the outer cylinder 2 additional cooling means

1, APEX oxygen bomb calorimeter flex fuel e85 structure

APEX oxygen bomb calorimeter flex fuel e85 shape with floor cabinet structure , the top left is an elastic closure
pressure openable cover ( commonly known as the cover ) and so on. Blenders
inner cylinder , the inner cylinder and the ignition temperature probe center electrode are
installed in the cover. The right is the operation of the instrument
panel LCD display and printer panel . Let the upper front power
switch : Power lead socket in the back of the upper instrument . APEX oxygen bomb calorimeter flex fuel e85 interior
include: SCM system , the amount of heating systems , water systems, electrical
control systems, power supplies and other accessories.

APEX oxygen bomb calorimeter flex fuel e85 SCM system comprising: a monolithic SBC ,
LCD, panel printer , keyboard , real time clock , etc. ;
calorimetry systems include : the amount of heat tube, oxygen bomb , temperature probe ( two-way ) , the temperature signal conditioning and conversion system ,
the ignition circuit and the inner cylinder mixer ;
water system comprises: an outer tube, storage tube, the water dosing device and a pipe connected thereto ,
solenoid valves , pumps, etc. : the electrical control system includes : ignition control ,
agitation control , solenoid valve and pump control as well as tips or alarm tone control and speakers .

2, APEX oxygen bomb calorimeter flex fuel e85 function

(1)APEX oxygen bomb calorimeter flex fuel e85 With a fully functional , accurate measurement,
calculation fine , intuitive display, Chinese interface, easy operation , high durability and
easy maintenance are intelligent automatic heat measuring device . (2), APEX oxygen bomb calorimeter flex fuel e85 AD imported high-grade large-scale integrated devices ,
to achieve dual high-speed , high-precision temperature measurement makes the operation easier
and more accurate measurements .

(3), APEX oxygen bomb calorimeter flex fuel e85 using large size graphic LCD display to display the various states of the instrument ,
data and graphics. Chinese menu interface , intuitive , friendly
and easy to use. Analog display temperature curve during the test , vivid and intuitive.

(4), APEX oxygen bomb calorimeter flex fuel e85 panel printer output using various reports .
Print format allows users to customize , or Jane or full , ready to set .

(5), APEX oxygen bomb calorimeter flex fuel e85 uses advanced real-time clock circuit can be displayed on the screen with the current date
and time are automatically recorded during the test time of completion of the test , and printed on the report ,
the test report more timely : to permanently record second date of calibration of the equipment to prepare for the next instrument
calibration confirmation date .

1, APEX oxygen bomb calorimeter flex fuel e85 calorimeter characteristics

( 1 ) simple operation, high degree of automation , 5 -step to the result

( 2 ) Measurement error : better than GB

( 3 ) without adjusting the water temperature inside and
outside the cylinder automatic quantitative water , quantitative error : ± 1g

( 4 ) the outer cylinder storage capacity, better thermal stability

( 5 ) on the use of ambient temperature requirements relaxed

( 6 ) can be modified voltage and frequency

2, APEX oxygen bomb calorimeter flex fuel e85 product characteristics value to customers

(1) calorimeter coal ratio for brick inside to provide accurate data ,
improve production quality bricks . Brick customers improve economic efficiency.

(2) The power plant customers calorimeter approach can accurately identify the total number of coal energy .
Grasp the cost of raw materials . Avoid the case of the data is not clear material cause economic losses.
One can not accurately detect plant raw calories . Day economic losses can buy dozens of the calorimeter .

(3) coke industry . Coke customized production, unable to leave
the accurate detection of heat . Will lead to coke quality fluctuated .

 

 
more..Other products from this supplier

[ ProductsSearch ]  [ [ Print ]  [ Close ]


Copyright © 2004 ChinaAseanTrade.com All rights reserved
中国-东盟自由贸易网版权所有@2004 沪lCP证05013507号