Calorimeter uses
1, APEX bomb calorimetry petroleum refinery called calorimeters, said domestic kcal instrument,
the main measure of coal, straw, bio-fuels and other solid amount of heat,
but also measurable heat oil and other liquids, mainly for thermal power, cement, coal, new energy and other fields.
2, APEX bomb calorimetry petroleum refinery widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.
3, APEX bomb calorimetry petroleum refinery according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.
4,APEX bomb calorimetry petroleum refinery 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.
5,APEX bomb calorimetry petroleum refinery commonly used assessment fuel combustion heat
can also be used to calculate the ratio of coal bricks.
Explosives equivalent research and development.
APEX bomb calorimetry petroleum refinery advantage
1, APEX bomb calorimetry petroleum refinery has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.
2, fast APEX APEX bomb calorimetry petroleum refinery is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .
3 , accurate APEX bomb calorimetry petroleum refinery according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.
4 , the history APEX founded 30 years long history , strong, development,
and manufacturing APEX bomb calorimetry petroleum refinery also has 20 years of history.
5 , maturity APEX bomb calorimetry petroleum refinery products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.
6 , cost and operation and maintenance costs APEX bomb calorimetry petroleum refinery because low energy consumption. Operating costs are not high .
Degree of automation is superior. Greatly reduce labor and maintenance costs . During use .
Human labor cost reduction is the process of liberation . Them . We focused on our customers ,
the implementation of low-cost supply of spare parts and consumables . Reduce the cost of consumables used .
1, APEX bomb calorimetry petroleum refinery structure
The right is the operation of the instrument
panel LCD display and printer panel . Let the upper front power
switch : Power lead socket in the back of the upper instrument . APEX bomb calorimetry petroleum refinery interior
include: SCM system , the amount of heating systems , water systems, electrical
control systems, power supplies and other accessories.
APEX bomb calorimetry petroleum refinery SCM system comprising: a monolithic SBC ,
LCD, panel printer , keyboard , real time clock , etc. ;
calorimetry systems include : the amount of heat tube, oxygen bomb , temperature probe ( two-way ) , the temperature signal conditioning and conversion system ,
the ignition circuit and the inner cylinder mixer ;
water system comprises: an outer tube, storage tube, the water dosing device and a pipe connected thereto ,
solenoid valves , pumps.
2, APEX bomb calorimetry petroleum refinery function
(1), APEX bomb calorimetry petroleum refinery using advanced single-chip microcomputer system ,
complete with instrumentation and unique water system
and the amount of thermal systems to auto-complete :
inner tube replacement and quantitative water cooling : automatic mixing , automatic ignition ,
data acquisition and processing, data storage , instrument status display , audible alert or alarm ,
printouts various reports . With a fully functional , accurate measurement,
calculation fine , intuitive display, Chinese interface, easy operation , high durability and
easy maintenance are intelligent automatic heat measuring device .
Simply install bomb lab technician manual operation , the instrument automatically completed by other processes .
(2), APEX bomb calorimetry petroleum refinery using large size graphic LCD display to display the various states of the instrument ,
data and graphics. Chinese menu interface , intuitive , friendly
and easy to use. Analog display temperature curve during the test , vivid and intuitive.
(3), APEX bomb calorimetry petroleum refinery uses advanced real-time clock circuit can be displayed on the screen with the current date
and time are automatically recorded during the test time of completion of the test , and printed on the report ,
the test report more timely : to permanently record second date of calibration of the equipment to prepare for the next instrument
calibration confirmation date . Normal time clock circuit outage .
3,APEX bomb calorimetry petroleum refinery specifications
( 1 ) , the heat capacity ( water equivalent ) : about 10500 J / K ( co 2500cal / K)
( 2 ) , oxygen bomb : Working pressure ( filling oxygen ) :2.8-3 .0 Mpa Max 3.2Mpa
Pressure test ( hydrostatic ): 20Mpa
Volumetric : 300mL
Weight : 2.5KS
Dimensions : Φ86mm × l81mm
( 3 ) , the inner barrel of water : about 2100mL
( 4 ) , the outer sleeve and water storage cartridges Capacity: Approximately 20L
( 5 ) , temperature measurement system :
Let the inner tube ( the probe in the roof ) and the outer sleeve ( probe with flange mounted on the outer wall of the sleeve ) ends ,
the corresponding screen is displayed as : IT or OT:
Display range : 0-65.535 ℃
Display resolution : 0.001 ℃
( 6 ) , heat capacity Repeatability: better than 0.1%
4, style="color:#0000cd;">APEX bomb calorimetry petroleum refinery Application Operation
APEX bomb calorimetry petroleum refinery calorimeter high degree of automation . Just a few steps to get the desired test results . Is very simple.
( 1 ) : Samples were weighed on a balance
( 2 ) : Weigh the sample into a bomb inside , and use our gift of automatic oxygenation apparatus filled with oxygen.
( 3 ) : the bomb into the calorimeter . And the sample weight and other data input calorimeter .
( 4 ) : Click : Start
( 5 ) : Waiting
( 6 ) : Wait......
( 7) : OK. Results are automatically begin printing
1, APEX bomb calorimetry petroleum refinery calorimeter characteristics
( 1 ) gay than the international market price of energy calorimeter low
( 2 ) than the international market prices of products with high performance .
Strong advanced degree .
( 3 ) long life , one year warranty . Repair rate is less than 2% a year
( 4 ) can be customized in different languages ,
so that he can use around the world
( 5 ) simple operation, high degree of automation , 5 -step to the result
( 6 ) Measurement error : better than GB
( 7 ) without adjusting the water temperature inside and
outside the cylinder automatic quantitative water , quantitative error : ± 1g
2, APEX bomb calorimetry petroleum refinery product characteristics value to customers
(1) calorimeter coal ratio for brick inside to provide accurate data ,
improve production quality bricks . Brick customers improve economic efficiency.
(2) The power plant customers calorimeter approach can accurately identify the total number of coal energy .
Grasp the cost of raw materials . Avoid the case of the data is not clear material cause economic losses.
One can not accurately detect plant raw calories . Day economic losses can buy dozens of the calorimeter .
(3) coke industry . Coke customized production, unable to leave
the accurate detection of heat . Will lead to coke quality fluctuated .