Brand:aa
Product detail:
Calorimeter uses
1, APEX heat capacity of calorimeter ISO1928: 1995 widely used. Coal mines, power plants and other areas of energy supply,
energy quality to be assessed. Which determines the price.
2, APEX heat capacity of calorimeter ISO1928: 1995 widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.
3, APEX heat capacity of calorimeter ISO1928: 1995 according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.
4,APEX heat capacity of calorimeter ISO1928: 1995 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.
5,APEX heat capacity of calorimeter ISO1928: 1995 commonly used assessment fuel combustion heat
can also be used to calculate the ratio of coal bricks.
Explosives equivalent research and development.
APEX heat capacity of calorimeter ISO1928: 1995 advantage
1, APEX heat capacity of calorimeter ISO1928: 1995 has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.
2, fast APEX APEX heat capacity of calorimeter ISO1928: 1995 is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .
3 , accurate APEX heat capacity of calorimeter ISO1928: 1995 according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.
4 , the history APEX founded 30 years long history , strong, development,
and manufacturing APEX heat capacity of calorimeter ISO1928: 1995 also has 20 years of history.
5 , maturity APEX heat capacity of calorimeter ISO1928: 1995 products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.
6,We have now done . Automatic water, automatic drainage ,
automatic printing , automatic calculation , automatic constant temperature inside and outside the barrel ,
automatic ignition, automatic temperature compensation, and other functions.
7,For the supply of goods services. increased from merely providing
maritime shipping services. Changes can now be based on customer demand ,
air or express delivery services. So that your home can directly get the desired device
1, APEX Sdf12structure
APEX heat capacity of calorimeter ISO1928: 1995 SCM system comprising: a monolithic SBC ,
LCD, panel printer , keyboard , real time clock , etc. ;
calorimetry systems include : the amount of heat tube, oxygen bomb , temperature probe ( two-way ) , the temperature signal conditioning and conversion system ,
the ignition circuit and the inner cylinder mixer ;
water system comprises: an outer tube, storage tube, the water dosing device and a pipe connected thereto ,
solenoid valves , pumps, etc. : the electrical control system includes : ignition control ,
agitation control , solenoid valve and pump control as well as tips or alarm tone control and speakers .
2, APEX heat capacity of calorimeter ISO1928: 1995 function
(1), APEX heat capacity of calorimeter ISO1928: 1995 AD imported high-grade large-scale integrated devices ,
to achieve dual high-speed , high-precision temperature measurement makes the operation easier
and more accurate measurements .
(2), APEX heat capacity of calorimeter ISO1928: 1995 using large size graphic LCD display to display the various states of the instrument ,
data and graphics. Chinese menu interface , intuitive , friendly
and easy to use. Analog display temperature curve during the test , vivid and intuitive.
(3), APEX heat capacity of calorimeter ISO1928: 1995 panel printer output using various reports .
Print format allows users to customize , or Jane or full , ready to set .
(4), APEX heat capacity of calorimeter ISO1928: 1995 uses advanced real-time clock circuit can be displayed on the screen with the current date
and time are automatically recorded during the test time of completion of the test , and printed on the report ,
the test report more timely : to permanently record second date of calibration of the equipment to prepare for the next instrument
calibration confirmation date . Normal time clock circuit outage .
3,APEX heat capacity of calorimeter ISO1928: 1995 specifications
( 1 ) , the heat capacity ( water equivalent ) : about 10500 J / K ( co 2500cal / K)
( 2 ) , oxygen bomb : Working pressure ( filling oxygen ) :2.8-3 .0 Mpa Max 3.2Mpa
Pressure test ( hydrostatic ): 20Mpa
Volumetric : 300mL
Weight : 2.5KS
Dimensions : Φ86mm × l81mm
( 3 ) , the inner barrel of water : about 2100mL
( 4 ) , the outer sleeve and water storage cartridges Capacity: Approximately 20L
( 5 ) , temperature measurement system :
Let the inner tube ( the probe in the roof ) and the outer sleeve ( probe with flange mounted on the outer wall of the sleeve ) ends ,
the corresponding screen is displayed as : IT or OT:
Display range : 0-65.535 ℃
Display resolution : 0.001 ℃
( 6 ) , heat capacity Repeatability: better than 0.1%
4, style="color:#0000cd;">APEX heat capacity of calorimeter ISO1928: 1995 Application Operation
APEX heat capacity of calorimeter ISO1928: 1995 calorimeter high degree of automation . Just a few steps to get the desired test results . Is very simple.
( 1 ) : Samples were weighed on a balance
( 2 ) : Weigh the sample into a bomb inside , and use our gift of automatic oxygenation apparatus filled with oxygen.
( 3 ) : the bomb into the calorimeter . And the sample weight and other data input calorimeter .
( 4 ) : Click : Start
( 5 ) : Waiting
( 6 ) : Wait......
(7): OK. Results are automatically begin printing
1, APEX heat capacity of calorimeter ISO1928: 1995 calorimeter characteristics
( 1 ) gay than the international market price of energy calorimeter low
( 2 ) than the international market prices of products with high performance .
Strong advanced degree .
( 3 ) long life , one year warranty . Repair rate is less than 2% a year
( 4 ) can be customized in different languages ,
so that he can use around the world
( 5 ) simple operation, high degree of automation , 5 -step to the result
( 6 ) Measurement error : better than GB
( 7 ) without adjusting the water temperature inside and
outside the cylinder automatic quantitative water , quantitative error : ± 1g
( 8 ) the outer cylinder storage capacity, better thermal stability
2, APEX heat capacity of calorimeter ISO1928: 1995 product characteristics value to customers
(1) The power plant customers calorimeter approach can accurately identify the total number of coal energy .
Grasp the cost of raw materials . Avoid the case of the data is not clear material cause economic losses.
One can not accurately detect plant raw calories . Day economic losses can buy dozens of the calorimeter .
(2) coke industry . Coke customized production, unable to leave
the accurate detection of heat . Will lead to coke quality fluctuated .