Brand:aa
Product detail:
CMS-series Electromagnetic Flow Switch
l Description
The flow switch principle is take use of the flow of liquid to drive the blade offset, to test whether the liquid is flowing. If the liquid does not flow, the blade in a natural state; If the liquid is flowing, the strike of the liquid driving the blade offset, through the transmission shaft to drive the switch action, and output the contact point signal.
l Features
u Couple with 5 different length blade, can be used in different pipe diameter, different situation.
u Can stand bigger medium pressure compare with the similar product in market.
u The flow volume can be adjustable.
u Simple Structure, high reliability.
l Specifications
Contact point capacity | 3A/250VAC |
Medium temperature | 0 ~ 100°C |
Contact point way | SPDT |
Installation pipe | 1-6″ |
Installation | 1″ NPT thread |
Press | ≤1MPa |
Blade Length | Pipe Diameter | |||||
| 1″ | 2″ | 3″ | 4″ | 5″ | 6″ |
1″ | 20-48 | 120-280 |
|
|
|
|
2″ |
| 40-140 | 180-470 | 350-920 |
|
|
3″ |
|
| 100-220 | 210-590 | 380-1400 |
|
4″ |
|
|
| 160-450 | 330-1200 |
|
5″ |
|
|
|
| 230-900 | 400-1800 |
| Range of the Flow adjust:(Unit:L/S) |
l Note of Installation
u Select the different length of the blade according the pipe or the size of the liquid cell.
u Indication arrow in accord with the direction of the liquid.
u Don’t adjust the flow screw too tight or loose.
u If there are some longer sundries such as the waterweeds,branch,metal wire in the liquid, need to prevent the blade be stucked.