SYD-0633 Tag open cup method Bitumen flash point tester

Click for original picture
Fob Price: 3000.00 USD/ 
MOQ: 1  
Payment Terms: delivery withindays since payment
Location: China
  Mr. Ben Ma    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:aa

Product detail:

 

 

 

 

 

SYD-0633  Tag open cup method Bitumen flash point tester

 

 

 

I. Summary of   Tag open cup method Bitumen flash point tester

 

     Liquid Petroleum Bitumen Flash Point Tester is used to determine flash point 

      of liquid petroleum bituminous materials, the flash point of which are lower than 93 °C.

 

 II.The main technical characteristics

 

   1. The use of special liquid heating system to sample heating, according 

    with the requirement of T 0633-1993 standard, ensure safety test. 

    Continuous adjustable heating power, to meet the requirements of the test.

 

   2.  Tag open cup method Bitumen  flash point tester is designed for desktop structure, stainless steel countertops 

      and stainless steel heating furnace shell, the beauty is generous.

 

   3.   Tag open cup method Bitumen flash point tester is Fully furnished,    the user can simply conduct a test with gas or other civil .

 

III. Main technical specifications and parameters

 

1.Power supply :

AC 220V±10%,50Hz

2.Sample cup ;

metal crucible (replace glass tag open cup);

 Depth 47 mm; 

the diameter of upper opening64 mm; 

the diameter of lower opening 38 mm;

 there is a mark line, which is 3.2 mm from the rim of upper opening, in the inner wall.

 

3.Thermal fluid bath cup 

0.3 the high quality carbon structural steel;

 The inner diameter of upper opening is100mm±5mm;

 High(50±5)mm;

The inner diameter of bottom is 56mm±2mm;

4.Igniter

It is composed of gas inlet pipe, gas flow adjustment valve and flame comparison ball. 

The diameter of spout is 0.7mm~0.8mm. 

The flame can be adjusted to 4 mm as per the relative standards.

5.The sample heating 

The heating system for sample liquid is composed of the heating furnace,

the thermal fluid bath cup and the sample cup.

You can control temperature rising rate through the heating adjustment device.

6.Thermometer:

 0°C~+100°C; the scale division is 1 °C; it is in accord with T0633

7.Gauge:

   Gauge: thickness 3.2 mm; there are two shape-point projections at the lower section.

 There is a hole of 4.0mm and a hole of 0.8 at 3.2 mm from the bottom.

8.Ambient temperature: 

≤35°C.

9.Relative humidity: 

≤85%.

 

 

 

 