Brand:aa
Product detail:
1.Introduction of heat pump heating house or hot water (instant & circulating)
instant heating
1).,the cop is more than 4.0, heat the water directly to 60C
2).the water temperature set freely
outlet water temperature constant, advanced water control system, heat the water to 60 diretly. Adjustable outlet water temperature.Adjust the water temperature(45-60)according to the need.
3).once adjusted, the unit outlet water temperature would be fixed on the set temperature.
4).the unit runs more stable, reliable without EHV(exceed high voltage).
5).water tank volume seleted freely, more practical
6).water and electricity system is completely separated, assure using safely
7).Intelligent control
With automatic filling water,water level control,defrost, power-fail memory,charge adjustment system,with booking timed heating,LCD display remote control and clock.
circulating
1):the cop is more than 4.0, more efficient
2).Meet a large consumption,stable and reliable hotwater output and performance,high energy efficiency ratio,constant water tank temperature to ensure comfortable use.
3). the unit runs more stable, reliable without EHV(exceed high voltage)
Debase efficiently the attenuation of the heat exchange rate,assure hot water capacity.Adopting high efficient tube heat exchanger, waster rate is greatly reduced, long-term and stable operation.
4).water tank volume seleted freely, more practical
5).water and electricity system is completely separated, assure using safely
6).Intelligent control
With automatic filling water,water level control,defrost, power-fail memory,charge adjustment system,with booking timed heating,LCD display remote control and clock.
2.The main parts of air water heat pump
3.The specifications of
ITEMS | UNIT | JK03R | JK03R | JK05R | JK10R | ||||
Heating capacity | KW | 10.6 | 10.6 | 18.0 | 35 | ||||
Cooling capacity | KW | 7.5 | 7.5 | 12.5 | 25 | ||||
Water yield | L/H | 245 | 245 | 420 | 810 | ||||
Compressor quantity | 1 | 1 | 1 | 2 | |||||
Input Power | KW | 2.8 | 2.8 | 4.68 | 9.3 | ||||
Voltage | V | 220-240 | 380-415 | ||||||
Rated frequency | Hz | 50 | |||||||
Rated current | A | 13 | 6 | 9 | 18 | ||||
Outlet temperature | °C | 70 | |||||||
Max temperature | °C | 75 | |||||||
Working-ambient temperature | -5°C~45°C | ||||||||
Cold water temperature drop | °C | 2-3 | |||||||
Protection grade | Ip×4 | ||||||||
Prevent electric shock | I | ||||||||
Noise | dB(A) | 50 | 50 | 52 | 55 | ||||
Compressor Brand | Hitachi/Copeland/Sanyo | ||||||||
Condenser Style | Coil(shell) | ||||||||
Evaporator Style | Hydrophilic aluminum foil | ||||||||
Refrigerant Category | Mixture type | ||||||||
Throttle | Thermal/electronic expansion valve | ||||||||
Control system | Multifunction, intelligent | ||||||||
Pipe size | mm | 25 | 25 | 25 | 40 | ||||
Package Dimension | L | mm | 750 | 750 | 750 | 1484 | |||
W | 690 | 690 | 690 | 730 | |||||
H | 870 | 870 | 1060 | 1060 | |||||
Weight | Kg | 120 | 120 | 165 | 320 | ||||
|
4.How do air water heat pump heating floor
5.Our clients and certificates