The performance class up to 21 kW

The Windy Boy 5000A and 6000A not only feature a maximum efficiency of 96.1 percent, but are also suited for the development of three-phase grid-feeding wind energy plants. The integrated SMA Power Balancer prevents undue load unbalance, and the plant is also able to feed-in even if individual phases fail. The weather-proof enclosure and the wide temperature range allow for installation at almost any location. Thanks to the OptiCool ventilation system, the equipment works at outdoor temperatures of up to 45 °C with maximum output. And in case of a problem: the worldwide SMA Service and comprehensive warranty program provide maximum security.

 

 

Efficiency

  • Up to 96.1 % efficiency
  • Can be combined to form three-phase units with up to 21 kW output
  • Integrated SMA Power Balancer
  • OptiCool: Continuous operation even at high temperatures


Easy to use

  • Free choice of installation site
  • Programmable polynomial curve enables free selection of turbines
  • Certified for the most countries (SMA Grid Guard)


Safe

  • Galvanic Isolation
  • Compatible with Windy Boy Protection Box 600


Reliable

  • Worldwide SMA Service including Serviceline
  • Comprehensive SMA warranty program

SMA Windy Boy 1100LV Inverters

Input (DC)     
Max. DC power 1210 W
Recommended generator power at 2500 / 5000
full-load hours per year  1000 W / 900 W
Max. DC voltage 60 V
"Min. open circuit voltage for activating Turbine Mode 25 V
"Operating range Turbine Mode 21 V – 60 V
Max. input current 62 A
      
Output (AC)     
AC nominal power 1000 W
Max. AC power 1100 W
Max. output current 5 A
Nominal AC voltage / AC operating range 220 V, 230 V, 240 V / 180 V – 260 V
AC grid frequency / range 50 Hz, 60 Hz / ± 4.5 Hz
Power factor (cos ) 1
Phase conductors / connection phases 1 / 1
      
Efficiency     
Max. efficiency / Euro-Eta 92.0 % / 90.4 %
      
Protective devices     
DC reverse-polarity protection     yes
AC short-circuit protection     yes
Ground fault monitoring     yes
Grid monitoring (SMA Grid Guard) yes
Galvanically isolated yes
      
General data     
Dimensions (W / H / D) in mm 434 / 295 / 214
Weight     29 kg
Operation temperature range –25 °C ... +60 °C
Internal consumption: Operation / standby < 5 W / 0.1 W
Topology LF transformer
Cooling concept Convection
Electronics protection rating / connection area (per IEC 60529) IP65 / IP65
Climatic category (per IEC 60721) 4K4H
      
Features     
DC connection: screw terminal     yes
AC connection: plug connector     yes
Display: text line / graphic     yes / —
Interfaces: RS485 / Bluetooth     opt. / opt.
Warranty: 5 years / 10 years     yes / opt.
Certificates and permits CE, VDE0126-1-1, G83/1, CER/06/190,
DK 5940, RD 1663, AS4777, EN 50438
      