Technical parameters of Gen-Set:
Power factor | COSΦ=0.8lagging |
Phase/wires | 3 phase 4 wires |
Start mode | Electric |
Fuel consumption: | 209L/h(at 100% Prime load) |
Rated currency(amps) | 256 |
Protection | Low oil-pressure, High water temperature, Over-speed, Over-current. |
Technical parameters of Engine:
Brand | Cummins | ||
Model | KTA38-G5 | Standby Power | 970kw/1212.5KVA |
Original: | Sino-U.S joint venture in China | Start mode | DC24V electric start |
Cylinders | 12 | Cylinders Layout | Line |
Fuel | 0# light diesel | Displacement | 37.8L |
Inter-Cooling | water inter-cooling | Speed-Governing | Electric |
Overload | 110% | Steady Speed Droop | ≤1% |
Technical parameters of Alternator:
Brand | Stamford | ||
Model | HCI-634H | Power | 752kw(940kva) |
Original | China & England joint venture in China | Rated voltage | 440/254v |
Protection | IP23 | Insulation | H |
Frequency fluctuation | ≤±0.5 % | Frequency regulation | ≤±0.5 %stable |
Voltage distortion | 4% | Voltage control | AVR |
Technical parameters of Control Panel:
Brand: Smartgen Model: 6310
Function:
·Start or Stop Generator set manually/ Automatically
·Open controller output can be defined as Pre-heat/Idle output
·High Coolant temperature protection
·Low Oil pressure protection
·Over load protection
·Generator over/under frequency protection
·Generator over/under/unbalance voltage Protection
·Over speed protection
·Over speed protection
·Available for remote control
NoteIndicate this function depend on the set points of the controller in field.
*Standard Accessories*
1. Accessories.
Single-bearing generator again drops. IP23. Insulation H
Radiator for 50 ambient temperature and double-deck cooling
Intelligent control panel with Regulator.
Electric start and 24v charger
Standard air filter, oil filter, fuel filter.
Cooling water tank
Daily base fuel tank. 250 liters(only for silent type).
High-efficient silencer.
Exhaust elbow
Storage battery
Switch for out-wire
Steel base-frame against vibration
Soft pipe for fuel and handle for lube going-out
Operation& Maintenance manual.
2. Testing conditions.
Standard Air Intake Temperature 25ºC
Air Intake Pressure 100kpa
Standard Light Diesel 0# or 10# Light diesel
Fuel Intake Temperature 40ºC
Air Intake Restriction 254mmHg
Exhaust Back Pressure 76mmHg
Lubricant Oil 15W40-CF4 Upgrade
3. Operation.
Continuous power: operate continuously for 24h in a day. 10% overload for
An hour is allowed in a 12 hours.
Standby power: this is used only when the civil power is off. Overload is not allowed.
Series of types be easy to choose for you with competitive price and super high quality:
All kinds of necesary accessaries:
Certification:
Newly Cummins diesel generator set catalog for your reference:
Thanks very much for your visit and any questions or ideas in your mind, pls be free to let me know through E-mail or your can go through our formal website: http://www.singfo.com/ .
Hope your visit on our factory in the furture time!