1. Models and specifications
Specifications of common products
Model |
Rated torque Nm |
Total Stroke time S |
Consumption W |
Power supply VAC |
|
GKR-010 |
100 |
30 |
54 |
70 |
Single phase 220 |
GKR-025 |
250 |
30 |
54 |
110 |
|
GKR-060 |
600 |
32 |
56 |
150 |
|
GKR-100 |
1000 |
40 |
56 |
150 |
|
GKR-160 |
1600 |
58 |
74 |
150 |
1. Main technical indicators
(1) Basic error limit, return difference and dead band under the corresponding level cane seen in the following table.
Angle |
Precision level |
Basic error limit |
Return difference |
Dead band |
0∽90° |
0.5% |
0.5% |
0.5% |
0.5% |
(2) Working conditions
Ambient temperature should be -20~70 ° C; relative humidity no more than 95%; environmental vibration no greater than 1.5G; no corrosive gas
(3) control signal (input signal)
4mA ~ 20mA 0 mA to 10 mA 1V to 5V 0V to 5V
(4) position feedback signal
4mA ~ 20mA (load resistance ≤ 500 Ω)
(5) power supply
Voltage 220V, Frequency 50HZ+1%
(6) Shell protection level complies with the standard GH4208 and accords with IP66
3. Installation, wiring and adjustment of the electric actuator
The intelligent electric actuator can be installed in various positions and the environment of the installation place should meet the requirements of the standard for the product. The outline overall and installing dimensions of the actuator can bee seen in the table below.
Model |
A |
B |
C |
D |
E |
H1 |
H2 |
H3 |
L |
1φ |
2φ |
Weight KG |
GKR-010 |
220±0.2 |
310 |
130±0.2 |
86 |
100±0.2 |
325 |
150 |
20 |
290 |
φ12 |
φ14thick15 |
30 |
GKR-025 |
260±0.2 |
345 |
100±0.2 |
115 |
120±0.2 |
345 |
170 |
20 |
315 |
φ14 |
φ16thick12 |
45 |
GKR-060 |
320±0.2 |
395 |
130±0.2 |
142 |
150±0.2 |
395 |
170 |
30 |
400 |
φ14 |
φ18thick23 |
50 |
GKR-100 |
320±0.2 |
395 |
130±0.2 |
142 |
150±0.2 |
395 |
210 |
30 |
400 |
φ14 |
φ18thick23 |
50 |
GKR-160 |
340±0.2 |
375 |
180±0.2 |
70 |
170±0.2 |
440 |
230 |
35 |
450 |
φ14 |
φ20thick25 |
60 |