Modular Type Air to Water Chiller/Air Cooled Chiller/Scroll Air Cooled Chiller/Industrial Chiller for Cooling Only
Two Kinds of Models:Air Cooled Water Chiller/Air to Water Chiller
1. Cooling Condition: Chilled Water In/Out 12°C/7°C;Cooling Water In/Out 30°C/35°C
Models: LT03AS-40AD
Cooling Capacity: 8KW-120KW
2.Cooling Condition: Chilled Glycol in/out -1/-5°C;Cooling Water In/Out 30°C/35°C
Models: LT03ASL-40ADL
Cooling Capacity: 4.7KW-61.6KW
Air Cooled Chiller Diagram:
FEATURE
1.Ready to work only after connected to chilled water system;
2.A stainless steel water vessel,a low noise pump have been fixed inside the chiller;
3.The chillers of capacity below 50KW is movable by wheels with them;
4.The chillers of capacity over 50KW are double refrigeration system design that is good to reduce the frequent start and stop for load change. The chillers can run even 1 system is in trouble.
5.Strict test and inspection has been made before the chillers are delivered.
Details As Follows:
MODEL LT- | 03AS | 05AS | 08AS | 10AS | 12AS | 15AS | 20AD | 25AD | 30AD | 40AD | |
Cooling Capacity | KW | 8.3 | 13.7 | 22.1 | 29.5 | 34 | 44.1 | 59 | 68 | 88.2 | 120 |
103kcal/hr | 7.1 | 11.8 | 19 | 25.4 | 29.2 | 37.9 | 50.7 | 58.5 | 75.9 | 103.2 | |
Power(kW) | 3.1 | 5 | 7.4 | 9.7 | 11.9 | 15.3 | 19.4 | 23.7 | 30.6 | 40.5 | |
Current(A) | 5.7 | 9.7 | 14.3 | 18.2 | 22.1 | 28.8 | 36.3 | 44.1 | 57.6 | 64.2 | |
Compressor | Quty(PCS) | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Power(kW) | 2.55 | 3.96 | 6.11 | 8.06 | 9.9 | 12.39 | 16.1 | 19.8 | 24.8 | 34.1 | |
Current(A) | 4.39 | 7.69 | 11.41 | 14.86 | 18.25 | 22.7 | 29.7 | 36.5 | 45.4 | 49.6 | |
Refrigerant | Type | R22 | |||||||||
Control | Thermal expension valve | ||||||||||
Fan | Power(KW) | 0.2 | 0.45 | 0.5 | 0.9 | 1.2 | 1.4 | 1.7 | 2.2 | 3.12 | 4.2 |
Current(A) | 0.6 | 0.9 | 1.4 | 1.8 | 2.3 | 2.9 | 5.4 | 7.6 | 9.6 | 10 | |
Water Pump | Type | Centrifugal pump | |||||||||
Power(KW) | 0.37 | 0.55 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | |
Current(A) | 0.75 | 1.1 | 1.5 | 1.5 | 1.5 | 3.2 | 3.2 | 3.2 | 4.6 | 4.6 | |
Pressure Head(mHo2) | 15 | 20 | 22 | 20 | 17 | 25 | 24 | 18 | 22 | 22 | |
Condenser | Type | Copper tupe and al fin | |||||||||
Evaporator | water pipe connection(mm) | DN25 | DN40 | DN50 | DN65 | ||||||
Water flow(L/min) | 23.7 | 39.3 | 63.4 | 84.6 | 97.5 | 126.4 | 169.1 | 194.9 | 252.8 | 344 | |
Water Tank | Volume(L) | 65 | 75 | 140 | 140 | 150 | 250 | 325 | 325 | 370 | 400 |
Fill,discharge, overflow port | DN20 | ||||||||||
Overall Size | Length mm | 1060 | 1060 | 1520 | 1620 | 1720 | 1810 | 2020 | 2270 | 2470 | 2670 |
Width mm | 740 | 740 | 850 | 850 | 850 | 930 | 1010 | 1150 | 1150 | 1240 | |
Hight mm | 1340 | 1450 | 1550 | 1600 | 1600 | 1730 | 1930 | 1930 | 2080 | 2220 | |
Weight | KG | 220 | 236 | 320 | 372 | 435 | 610 | 750 | 850 | 950 | 1050 |
Remark:1.Colling Condition:Chilled water in/out 12/7°C;Ambient Temperature 35°C; | |||||||||||
2.Suitable chilled water temperature:9-25°C; | |||||||||||
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%; | |||||||||||
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need; | |||||||||||
5.There may be Changes for improvement without notice, confirm always before your order. |