Vibration monitoring system, vibration monitor for wind power station(Version for Wind power station)
1) High reliability
- Fully Integrated structure:integrates with signal conditioning,power supply,data processing and communication module, without wearing parts such as hard disk and fan.
- IP65 Protection grade:The on site collection box of RH1000 has dustproof and waterproof protection grade IP65, ensured the collection box can be used on industrial site for long time, defended influence of dust and smeary.
- Design of the lower consumption:Application of industrial ARMl chip, greatly reduced the heat emission of hardware, can work in high temperature industrial field without cooling fan assembly. Avoid the situation of much high temperature caused by PC104.
- Hardware protection:Application of firmware and watch dog circuit, ensured system stability; avoid the damage of computer viruses
- LCD: System implemented 5.7 inches LCD, users can browse the working status and data dynamic display of system on site, .
- Completed self-checking function:Modularity application design, can inspect every independent part of the condition, and present the exceptional report to the software system in time.
2) Accurately and completely data collection.
3) Realize synchronous sampling at any two channels
4) Good scalability
3. Main technical parameters
Maximal input Channels | 16 channels for vibration 8 channels for Process information, 2 channels for tacho | |
Maximal output channels | 1 line for relay, dry contact | |
Vibration signal input | ||
Channels | Max.16 Channels, 8,12,16 Optional synchronous sampling at 4 channels, synchronous sampling at any two channels | |
Compatible transducers | Accelerometer, Velocity Pickups, Non-contact Eddy Current Displacement Probes, voltage transducer, 4~20mA | |
Input | ±10V | |
Transducer driver current | 4mA@24V; Constant current source used for ICP model acceleration transducer | |
A/D conversion | 24 bit | |
Input impedance | 220K | |
Physical quantity | Acceleration, velocity, displacement, user-defined | |
Integral | Once integral, twice integral | |
Accelerometer maximum | 80g, 200mm/s, 10mm, Using 100mV/g transducer | |
Fmax Frequency Fmax | 100Hz –10kHz;9 Position (100,200,500,1K,2K,4K,5K,8K,10K) | |
Sampling rate | 256Hz ~25.6kHz; 9 Position (256,512,1024,2560,5120,10240,12800,256000) | |
Dynamic.signal range | 95dB | |
Harmonic distortion | <-70dB,Other distortion and noise will be lower | |
precision | 1%( 0.1dB), 80Hz | |
Lines | 400,800,1600,3200,6400 | |
Time domain sampling | 1024,2048,4096,8192,16384 | |
Window function | Hanning, Rectangle window | |
Averaging type | Linearity, peak hold | |
Averaging times | 1,2,4,8,16,32,64 | |
Process information | ||
Channels | 8, Isolation input | |
Signal range | ±12V or 4~20mA | |
Rotating speed | ||
Channels | 2 | |
Compatible type | TTL, Eddy current, Hall, | |
Triggering level | ±2V~±30Vpp | |
Electric relay output | ||
Channels | 1 | |
Type | SPST, Normally open or close | |
Voltage and current | 250V AC,2A | |
Control terminals | Server | |
Regular index | ||
Communications | 1)Ethernet v2.0. IEEE802.3, TCP/IP, 10/100baseT 2)Wireless network | |
Memory capacity | 256M | |
Dimensions | 360×260×150, metal shell | |
Protection grade | IP65,waterproof, dust proof | |
Temperature range | (-40 ~ 60)°C | |
Humidity | 95% RH without condensate | |
Electromagnetism compatible authentication | ||
Passed the following tests: 1.Electrostatic discharge interference test 2. RFEMS test 3. Electrical fast transient impulses interference test 4. Surging interference test 5. Damped oscillatory wave immunity test 6. power frequency disturbance of magnetic field test 7. Voltage sags, short interruptions and voltage variations immunity test | ||
Anti-explosion options | ||
Anti-explosion indentification | ExibIIAT4 | Monitoring station |
Exd[ib]IIAT4 | Anti-explosion power source |