Add to Favorite | Set Home | Casual look | Mobile

Hangzhou Nuohan Electronics Co., Ltd.

Company Profile

 Hangzhou Nuohan Electronics Co., Ltd.

China

category
  • No Category
Site Search
 
link
  • No Links
Current:Home » Product Categories » » Meanwell 100W 24V Single Output Switching Power Supply led driver 24v
Similar products
Meanwell 100W 24V Single Output Switching Power Supply led driver 24v
Click to enlarge
Product:
Brand: aa 
Price: 10.00USD/ 
MOQ: 10  
Total supply:
Delivery time: From the date of payment from the buyer within days of delivery
update time: 2023-05-28 01:00  Valid to:Long-term effective
  Inquiry
Profile

MODEL

PLN-100-24

OUTPUT

DC VOLTAGE

24V

CONSTANT CURRENT REGION   Note. 6

18 ~ 24V

RATED CURRENT          Note. 5

4A

RATED POWER             Note. 5

96W

RIPPLE & NOISE (max.)         Note.2

150mVp-p

VOLTAGE ADJ. RANGE (SVR1

20.4 ~ 24V

CURRENT ADJ. RANGE(SVR2)

3 ~ 4A

VOLTAGE TOLERANCE         Note.3

±3.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME

1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load

HOLD UP TIME (Typ.)

60ms/230VAC 30ms/115VAC at full load

INPUT

VOLTAGE RANGE           Note.4

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47~63HZ

POWER FACTOR (Typ.)

PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

EFFICIENCY (Typ.)

88.5%

AC CURRENT (Typ.)

1.1A/115VAC 0.55A/230VAC 0.45A/277VAC

INRUSH CURRENT (Typ.)

COLD START 40A(twidth=1030us measured at 50% Ipeak) at 230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER CURRENT

95 ~ 102%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

27 ~ 34V

Protection type : Shut down and latch off o/p voltage, re-power on to recover

OVER TEMPERATURE

90°C±10°C ( RTH2)

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30~ +50°C(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80°C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY&EMC

SAFETY STANDARDS  

UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1,CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950-1

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C( >75% load); EN61000-3-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A

QTHERS

MTBF

303.1K hrs min. MIL-HDBK-217F (25°C)

DIMENSION

200*70.5*35mm (L*W*H)

PACKING

0.52Kg; 20pcs/12.5Kg/0.76CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage, please check the static characteristic for more details.

5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.

6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part 18.

8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inquiry list