MODEL | PLN-100-24 | |
OUTPUT | DC VOLTAGE | 24V |
CONSTANT CURRENT REGION Note. 6 | 18 ~ 24V | |
RATED CURRENT Note. 5 | 4A | |
RATED POWER Note. 5 | 96W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE (SVR1 | 20.4 ~ 24V | |
CURRENT ADJ. RANGE(SVR2) | 3 ~ 4A | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | |
LINE REGULATION | ±1.0% | |
LOAD REGULATION | ±2.0% | |
SETUP, RISE TIME | 1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 60ms/230VAC 30ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47~63HZ | |
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |
EFFICIENCY (Typ.) | 88.5% | |
AC CURRENT (Typ.) | 1.1A/115VAC 0.55A/230VAC 0.45A/277VAC | |
INRUSH CURRENT (Typ.) | COLD START 40A(twidth=1030us measured at 50% Ipeak) at 230VAC | |
LEAKAGE CURRENT | <0.75mA / 240VAC | |
PROTECTION | OVER CURRENT | 95 ~ 102% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 27 ~ 34V | |
Protection type : Shut down and latch off o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | 90°C±10°C ( RTH2) | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -30~ +50°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +80°C, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1,CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25°C/ 70% RH | |
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C( >75% load); EN61000-3-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | |
QTHERS | MTBF | 303.1K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 200*70.5*35mm (L*W*H) | |
PACKING | 0.52Kg; 20pcs/12.5Kg/0.76CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage, please check the static characteristic for more details. 5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part 18. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. |