OBFW10-VFX3648 FLEXware QUAD Battery Based Power System
Model | Part Number | Output Watts | Output Current | Voltage DC/AC | Type | Inverter |
OBFW10-VFX3648 FLEXware QUAD | 03300379 | 14,400 | 70 Amps | 48 / 120/240V | Off-Grid | 4 - VFXFX3648 |
Outback VFX Series Inverter Specifications
Sealed Models | Vented Models | |||||
---|---|---|---|---|---|---|
FX2012T | FX2524T | FX3048T | VFX2812 | VFX3524 | VFX3648 | |
Nominal DC Input Voltage | 12 VDC | 24 VDC | 48 VDC | 12 VDC | 24 VDC | 48 VDC |
Continuous Power Rating at 25° C | 2000 VA | 2500 VA | 3000 VA | 2800 VA | 3500 VA | 3600 VA |
AC Voltage/Frequency | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz |
Continuous AC RMS Output at 25° C | 17.0 amps AC | 20.8 amps AC | 25.0 amps AC | 23.3 amps AC | 29.2 amps AC | 30.0 amps AC |
Full Idle Power | ≈ 20 Watts | ≈ 20 Watts | ≈ 23 Watts | ≈ 20 Watts | ≈ 20 Watts | ≈ 23 Watts |
Search | ≈ 6 Watts | ≈ 6 Watts | ≈ 6 Watts | ≈ 6 Watts | ≈ 6 Watts | ≈ 6 Watts |
Typical Efficiency | 90% | 92% | 93% | 90% | 92% | 93% |
Typical Total Harmonic Distortion | 2% | 2% | 2% | 2% | 2% | 2% |
Maximum | 5% | 5% | 5% | 5% | 5% | 5% |
Output Voltage Regulation | ± 2% | ± 2% | ± 2% | ± 2% | ± 2% | ± 2% |
Peak Maximum Output Current | 56 amps AC | 70 amps AC | 70 amps AC | 56 amps AC | 70 amps AC | 70 amps AC |
RMS | 40 amps AC | 50 amps AC | 50 amps AC | 40 amps AC | 50 amps AC | 50 amps AC |
Surge AC Overload Capability | 4800 VA | 6000 VA | 6000 VA | 4800 VA | 6000 VA | 6000 VA |
5 Second | 4000 VA | 4800 VA | 4800 VA | 4000 VA | 5000 VA | 5000 VA |
30 Minutes | 2500 VA | 3200 VA | 3200 VA | 3200 VA | 4000 VA | 4000 VA |
AC Input Current Maximum | 60 amps AC | 60 amps AC | 60 amps AC | 60 amps AC | 60 amps AC | 60 amps AC |
AC Input Voltage Range (MATE Adjustable) | 80 to 150 VAC | 80 to 150 VAC | 80 to 150 VAC | 80 to 150 VAC | 80 to 150 VAC | 80 to 150 VAC |
AC Input Frequency Range | 54 to 66 Hz | 54 to 66 Hz | 54 to 66 Hz | 54 to 66 Hz | 54 to 66 Hz | 54 to 66 Hz |
DC Input Voltage Range | 10.5 to 17.5 VDC | 21.0 to 34.0 VDC | 42.0 to 68.0 VDC | 10.5 to 17.0 VDC | 21.0 to 34.0 VDC | 42.0 to 68.0 VDC |
Continuous Battery Charge Output | 80 amps DC | 55 amps DC | 35 amps DC | 125 amps DC | 85 amps DC | 45 amps DC |
Warranty | Standard 2 year / Optional 5 year | Standard 2 year / Optional 5 year | ||||
Unit Weight | 56 lbs (25 kg) | 54 lbs (25 kg) | ||||
Shipping | 67 lbs (30 kg) | 62.2 lbs (28 kg) | ||||
Unit Dimensions (H x W x L) | 13 x 8.25 x 16.25" (33 x 21 x 41 cm) | 12 x 8.25 x 16.25" (30 x 21 x 41 cm) | ||||
Shipping | 21.75 x 13 x 22" (55 x 33 x 56 cm) | 21.75 x 13 x 22" (55 x 33 x 56 cm) |
FLEXmax 80 Specifications | FLEXmax 60 Specifications | |
---|---|---|
Nominal Battery Voltages | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) |
Maximum Output Current | 80 amps @ 104° F (40°C) with adjustable current limit | 60 amps @ 104° F (40°C) with adjustable current limit |
Maximum Solar Array STC Nameplate | 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts | 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts |
NEC Recommended Solar Array STC Nameplate | 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts | 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts |
PV Open Circuit Voltage (VOC) | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum |
Standby Power Consumption | Less than 1 Watt typical | Less than 1 Watt typical |
Power Conversion Efficiency | 97.5% @ 80 Amps in a 48 VDC System - Typical | 98.1% @ 60 Amps in at 48 VDC System voltage - Typical |
Charging Regulation | Five Stages: Bulk, Absorption, Float, Silent and Equalization | Five Stages: Bulk, Absorption, Float, Silent and Equalization |
Voltage Regulation Set points | 10 to 80 VDC user adjustable with password protection | 10 to 80 VDC user adjustable with password protection |
Equalization Charging | Programmable Voltage Set point and Duration - Automatic Termination when completed | Programmable Voltage Set point and Duration - Automatic Termination when completed |
Battery Temperature Compensation | Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell | Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell |
Voltage Step-Down Capability | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input |
Programmable Auxiliary Control Output | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) |
Status Display | 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total | 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total |
Remote Display and Controller | Optional Mate or Mate2 with RS232 Serial Communications Port | Optional Mate or Mate2 with RS232 Serial Communications Port |
Network Cabling | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
Data Logging | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production |
Hydro Turbine Applications | Consult factory for approved Turbines | Consult factory for approved Turbines |
Positive Ground Applications | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
Operating Temperature Range | Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) | Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) |
Environmental Rating | Indoor Type 1 | Indoor Type 1 |
Conduit Knockouts | One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom | One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom |
Warranty | Standard 5 year / Available 10 Year | Standard 5 year / Available 10 Year |
Weight - Unit | 12.20 lbs (5.56 kg) | 11.65 lbs (5.3 kg) |
- Shipping | 15.75 lbs (7.10 kg) | 14.55 lbs (6.4 kg) |
Dimensions - Unit | 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) - (H x W x D) | 13.5 x 5.75 x 4" (40 x 14 x 10 cm) |
- Shipping | 21" x 10.5" x 9.75" (53 x 27 x 25 cm) | 18 x 11 x 8" (46 x 30 x 20 cm) |
Options | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 |
Menu Languages | English & Spanish | English & Spanish |