OBFW10-VFX3648 FLEXware QUAD Battery Based Power System

ModelPart NumberOutput WattsOutput CurrentVoltage DC/ACTypeInverter
OBFW10-VFX3648 FLEXware QUAD0330037914,40070 Amps48 / 120/240VOff-Grid4 - VFXFX3648

 

 

Outback VFX Series Inverter Specifications

 Sealed ModelsVented Models
FX2012TFX2524TFX3048TVFX2812VFX3524VFX3648
Nominal DC Input Voltage12 VDC24 VDC48 VDC12 VDC24 VDC48 VDC
Continuous Power Rating at 25° C2000 VA2500 VA3000 VA2800 VA3500 VA3600 VA
AC Voltage/Frequency120 VAC 60 Hz120 VAC 60 Hz120 VAC 60 Hz120 VAC 60 Hz120 VAC 60 Hz120 VAC 60 Hz
Continuous AC RMS Output at 25° C17.0 amps AC20.8 amps AC25.0 amps AC23.3 amps AC29.2 amps AC30.0 amps AC
Full Idle Power≈ 20 Watts≈ 20 Watts≈ 23 Watts≈ 20 Watts≈ 20 Watts≈ 23 Watts
Search≈ 6 Watts≈ 6 Watts≈ 6 Watts≈ 6 Watts≈ 6 Watts≈ 6 Watts
Typical Efficiency90%92%93%90%92%93%
Typical Total Harmonic Distortion2%2%2%2%2%2%
Maximum5%5%5%5%5%5%
Output Voltage Regulation± 2%± 2%± 2%± 2%± 2%± 2%
Peak Maximum Output Current56 amps AC70 amps AC70 amps AC56 amps AC70 amps AC70 amps AC
RMS40 amps AC50 amps AC50 amps AC40 amps AC50 amps AC50 amps AC
Surge AC Overload Capability4800 VA6000 VA6000 VA4800 VA6000 VA6000 VA
5 Second4000 VA4800 VA4800 VA4000 VA5000 VA5000 VA
30 Minutes2500 VA3200 VA3200 VA3200 VA4000 VA4000 VA
AC Input Current Maximum60 amps AC60 amps AC60 amps AC60 amps AC60 amps AC60 amps AC
AC Input Voltage Range (MATE Adjustable)80 to 150 VAC80 to 150 VAC80 to 150 VAC80 to 150 VAC80 to 150 VAC80 to 150 VAC
AC Input Frequency Range54 to 66 Hz54 to 66 Hz54 to 66 Hz54 to 66 Hz54 to 66 Hz54 to 66 Hz
DC Input Voltage Range10.5 to 17.5 VDC21.0 to 34.0 VDC42.0 to 68.0 VDC10.5 to 17.0 VDC21.0 to 34.0 VDC42.0 to 68.0 VDC
Continuous Battery Charge Output80 amps DC55 amps DC35 amps DC125 amps DC85 amps DC45 amps DC
WarrantyStandard 2 year / Optional 5 yearStandard 2 year / Optional 5 year
Unit Weight56 lbs (25 kg)54 lbs (25 kg)
Shipping67 lbs (30 kg)62.2 lbs (28 kg)
Unit Dimensions (H x W x L)13 x 8.25 x 16.25" (33 x 21 x 41 cm)12 x 8.25 x 16.25" (30 x 21 x 41 cm)
Shipping21.75 x 13 x 22" (55 x 33 x 56 cm)21.75 x 13 x 22" (55 x 33 x 56 cm)
 FLEXmax 80 SpecificationsFLEXmax 60 Specifications
Nominal Battery Voltages12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
Maximum Output Current80 amps @ 104° F (40°C) with adjustable current limit60 amps @ 104° F (40°C) with adjustable current limit
Maximum Solar Array STC Nameplate12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts
NEC Recommended Solar Array STC Nameplate12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts
PV Open Circuit Voltage (VOC)150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
Standby Power ConsumptionLess than 1 Watt typicalLess than 1 Watt typical
Power Conversion Efficiency97.5% @ 80 Amps in a 48 VDC System - Typical98.1% @ 60 Amps in at 48 VDC System voltage - Typical
Charging RegulationFive Stages: Bulk, Absorption, Float, Silent and EqualizationFive Stages: Bulk, Absorption, Float, Silent and Equalization
Voltage Regulation Set points10 to 80 VDC user adjustable with password protection10 to 80 VDC user adjustable with password protection
Equalization ChargingProgrammable Voltage Set point and Duration - Automatic Termination when completedProgrammable Voltage Set point and Duration - Automatic Termination when completed
Battery Temperature CompensationAutomatic with optional RTS installed / 5.0 mV per °C per 2V battery cellAutomatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
Voltage Step-Down CapabilityCan charge a lower voltage battery from a higher voltage PV array - Max 150 VDC inputCan charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
Programmable Auxiliary Control Output12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
Status Display3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
Remote Display and ControllerOptional Mate or Mate2 with RS232 Serial Communications PortOptional Mate or Mate2 with RS232 Serial Communications Port
Network CablingProprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
Data LoggingLast 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of productionLast 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
Hydro Turbine ApplicationsConsult factory for approved TurbinesConsult factory for approved Turbines
Positive Ground ApplicationsRequires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
Operating Temperature RangeMinimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Environmental RatingIndoor Type 1Indoor Type 1
Conduit KnockoutsOne 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottomOne 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
WarrantyStandard 5 year / Available 10 YearStandard 5 year / Available 10 Year
Weight - Unit12.20 lbs (5.56 kg)11.65 lbs (5.3 kg)
         - Shipping15.75 lbs (7.10 kg)14.55 lbs (6.4 kg)
Dimensions - Unit16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
13.5 x 5.75 x 4" (40 x 14 x 10 cm)
         - Shipping21" x 10.5" x 9.75" (53 x 27 x 25 cm)18 x 11 x 8" (46 x 30 x 20 cm)
OptionsRemote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2
Menu LanguagesEnglish & SpanishEnglish & Spanish

 