Made in China electrical power cable pvc pe xlpe cable
electric power cable Construction
Phase Conductor: Aluminium(optional)
Neutral Non-messenger Conductor: Aluminium(optional)
Neutral Messenger Conductor: Aluminium Alloy(optional)
Street Lighting Conductor: Aluminium(optional)
Insulation: XLPE or PE or PVC(weathering resistance)
Standard:NF C33-209, BS 7870-5, GB/T 12527, IEC 60502 etc.
Specifications of electric power cable
SPEC mm2 | conductor structure |
|
|
| Approx. |
|
| |
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) |
| (mm) | (mm) | (kg/km) | Drum | |
1x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1x70+1x70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1x95+1x95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2x70+1x70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2x95+1x95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3x70+1x70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2x95+1x95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m |
Operating Characteristics
Rated Voltage: Up to and including 0.6/1(1.2)kV
Max. Operating Temperature of Conductor: 90°C(XLPE), 70°C(PE), 70°C(PVC)
Max. Short-circuit Temperature of Conductor: 250°C(XLPE), 130°C(PE), 160°C(PVC)
Min. Ambient Temperature under Installation: -20°C
Optional Information
- Payment : L/C,T/T.
- Delivery : 20days or depending on your demand.
- Origin : China (Mainland)
- Minimum Order : 100M
- Packaging : standard export wooden drum/steel wooden drum.
About us
If you are interested in any of our products, pls contact us at any time. We will response in 24hours.