1. General Introduction
Conductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Applications of Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting applications. And for service at 600 volts or lower where conductor temperature can’t exceed 75°C maximum.
2. Application
In the areas such as downtown, factory and other populated and densely built areas, the replacement of bare conductor by abc cables in transmission and distribution lines can bring the benifits of reducing accidents and guarantee the stability of power supply. Compared with the underground power cable, overhead insulated line can bring down the costs of lining and maintaining considerably.
3. Product Features:
1. Rated voltage U0 / U: 0.6/1kV
2. The cable conductor long term working temperature should not be exceeded:
* Polyvinyl chloride, polyethylene aerial insulated cable 70 °C
* XLPE aerial insulated cable 90 °C
3. When short circuit (Max 5 seconds), the conductor temperature can not be exceed:
* PVC insulated aerial cable 160 °C
* Polyethylene insulated aerial cable 130 °C
* XLPE insulated aerial cable 250 °C
* The ambient temperature of laying cable can not be lower than -20 °C
4. Facilities
5. Package
6. Specifications
SPEC mm2 | conductor structure |
|
|
| Approx. |
|
| |
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) |
| (mm) | (mm) | (kg/km) | Drum | |
1x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1x70+1x70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1x95+1x95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2x70+1x70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2x95+1x95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3x16+1x16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3x25+1x25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3x35+1x35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3x50+1x50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3x70+1x70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2x95+1x95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m |