DC to AC Pure sine wave Hybrid inverter and controller
100W 300W 500W 1000W 1500W 2000W 3000W 4000W 5000W 6000W
CPU intelligent management,
Adopted best electric components, stable quality, long-life,
The high conversion efficiency( 87%-98%)
Low power consumption,1W~6W under sleep state.
DC to AC Pure sine wave inverter with sleep mode 2000W
Top Level Quality Pure Sine Wave Inverter 2000W
With battery charger & UPS
CPU intelligent management,
Adopted best electric components, stable quality, long-life,
The high conversion efficiency( 87%-98%)
Low power consumption,1W~6W under sleep state.
Specification
Model | LMI-1 | LMI-3 | LMI-5 | LMI-10 | LMI-15 | LMI-20 | LMI-30 | LMI-40 | LMI-50 | LMI-60 | |||||||||||
Power Rating (W) | 100 | 300 | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | |||||||||||
Battery Voltage (V) | 12/24 | 12/24/48 | 24/48 | ||||||||||||||||||
Solar Panel | Maximum Voltage (V) | 25/50 | 50 | 100 | 100 | ||||||||||||||||
Solar Panel | Maximum Current (A) | 20 | 40 | 60 | 70 | ||||||||||||||||
Solar Panel | MPPT Function | user option | |||||||||||||||||||
Inverter Output | Voltage (V) | 220±3% | |||||||||||||||||||
Inverter Output | Frequency (Hz) | 50±0.5 | |||||||||||||||||||
Inverter Output | Wave Form | pure sine wave | |||||||||||||||||||
Inverter Output | THD (%) | ≤ 3% for linear load,<5% for nonlinear load , all of them in full load condition | |||||||||||||||||||
Inverter Output | Dynamic Response Time (ms) | <10 | |||||||||||||||||||
Inverter Output | Efficiency (%) | Max 90% | |||||||||||||||||||
Inverter Output | Overload Capacity | overload 120% or short circuit automatically shut off the inverter, 1 second after automatic restart the inverter | |||||||||||||||||||
Line complementary Input | 220V/50Hz/60Hz | ||||||||||||||||||||
Line complementary output | DC priority design ,when battery voltage is too low, the inverter output is turned by line bypass output to load User option | ||||||||||||||||||||
DC Output | USB Power Supply | User option | |||||||||||||||||||
DC Output | 12V DC Power Supply | ||||||||||||||||||||
Operating Temperature(°C) | -40 — +50 | ||||||||||||||||||||
Type of Cooling | temperature control forced ventilation | ||||||||||||||||||||
Relative Humidity (%) | 0-90% non-condensate | ||||||||||||||||||||
Indication LED Indicator | solar panel (blue), battery normal (yellow , when battery capacity left 10% ,the yellow LED will flash ), Battery failure(red), power start (green/red ,if you use manned , the green LED light ,if you use atomic ,the red LED light, inverter normal (yellow), line normal (green) | ||||||||||||||||||||
Protection Function | output overload and short circuit, battery low voltage and over charging protection, solar panel Polarity reverse connect protection, overheating protection, lightning protection | ||||||||||||||||||||
Cooling | By automatic control fan cooling | ||||||||||||||||||||
Physical Size (LW×H)(cm) | 14*9*3 | 23.8*12.6*9.5 | 45*25*11.3 | 63*25*13.8 | |||||||||||||||||
Net Weight (Kg) | 0.3 | 2.3 | 2.6 | 2.8 | 4.5 | 4.9 | 6.8 | 7.5 | 8.5 | 9 |