Copper Conductor XLPE Insulated Steel Wire Armored Power Cable Flame Retardent Armoured Cable
Introduction
This cable has special fire resistant coating so it has excellent heat resistant and fire resistant performance. During fire evacuations, it is important for critical electrical installations to perform their functions; these include fire alarms, smoke detectors, sprinklers, emergency lighting, and exit lights. We conduct stringent tests by simulating the environment for our fire resistant cables to ensure that they pass the safety requirements and perform during such emergencies.
Standard
Refer IEC60502-1,BS6387, SS299-1, IEC60331, IEC60332-1, IEC60332-3, IEC60754, IEC61034
Feature
1 Direct Wiring and No need Pipe or Fire Protection Measures
2 Except Fire Resistant Coating and Coating, the Cable Connection method and Terminal Processing are same with Normal Cables
3 The Cable Outer Diameter increases a little because of Fire Resistant Coating.
Application
It is mainly used for Control,Monitoring,Guidance and Alarm System of Fire Flighting Device for Modern City Buildings and Places that have high safety requirements, such as emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, lifts, escalators, and high-rise buildings.
Fire Performance
Type | Flame | Continued Fire Time (min) | Test Result |
A | 950-1000 | 90 | 3A Fuse Not Blow |
B | 750-800 | 90 | 3B Fuse Not Blow |
Construction
Conductor: Solid or Stranded Copper or tinned copper conductor
Insulation: Mica glass tape covered by cross-linked XLPE compound
Or Mica glass tape covered by PE or PVC
Inner Sheath (optional):Thermoplastic LSZH compound type
Armouring (optional): Steel Tape or Galvanised Steel Wire or Aluminum Wire
Outer Sheath:Thermoplastic LSZH compound type
Model, Name
Model | Name | |||||
KYV/NHA KYV/NHB KYJV/NHA KYJV/NHB kVY/NHB | CU Core PE Insulated PVC Sheathed Type A Control Cable CU Core PE Insulated PVC Sheathed Type B Control Cable CU Core XLPE Insulated PVC Sheathed Type A Control Cable CU Core XLPE Insulated PVC Sheathed Type B Control Cable CU Core PVC Insulated PVC Sheathed Type B Control Cable | |||||
KYV22/NHA KYV22/NHB KYJV22/NHA KYJV22/NHB kVV22/NHB | Note:Steel Tape Armoured(STA) for the following cables CU Core PE Insulated PVC Sheathed Type A Control Cable CU Core PE Insulated PVC Sheathed Type B Control Cable CU Core XLPE Insulated PVC Sheathed Type A Control Cable CU Core XLPE Insulated PVC Sheathed Type B Control Cable CU Core PVC Insulated PVC Sheathed Type B Control Cable | |||||
KYV32/NHA KYV32/NHB KYJV32/NHA KYJV32/NHB kVV32/NHB | Note:Thin Steel Wire Armoured(SWA) for the following cables CU Core PE Insulated PVC Sheathed Type A Control Cable CU Core PE Insulated PVC Sheathed Type B Control Cable CU Core XLPE Insulated PVC Sheathed Type A Control Cable CU Core XLPE Insulated PVC Sheathed Type B Control Cable CU Core PVC Insulated PVC Sheathed Type B Control Cable | |||||
YV/NHA YV/NHB YJV/NHA YJV/NHB VV/NHB | CU Core PE Insulated PVC Sheathed Type A Power Cable CU Core PE Insulated PVC Sheathed Type B Power Cable CU Core XLPE Insulated PVC Sheathed Type A Power Cable CU Core XLPE Insulated PVC Sheathed Type B Power Cable CU Core PVC Insulated PVC Sheathed Type B Power Cable | |||||
YV22/NHA YV22/NHB YJV22/NHA YJV22/NHB VV22/NHB | Note:Steel Tape Armoured(STA) for the following cables CU Core PE Insulated PVC Sheathed Type A Power Cable CU Core PE Insulated PVC Sheathed Type B Power Cable CU Core XLPE Insulated PVC Sheathed Type A Power Cable CU Core XLPE Insulated PVC Sheathed Type B Power Cable CU Core PVC Insulated PVC Sheathed Type B Power Cable | |||||
YV32/NHA YV32/NHB YJV32/NHA YJV32/NHB VV32/NHB | Note:Thin Steel Wire Armoured(SWA) for the following cables |