Welcome to the world of MEAN WELL!
RPS-60-12
Product Pictures
Here is the detailed info for my meanwell 60w medical type open frame 12v with CB&CE&UL&cUL . Hope you like it.
Product Details
(upside view)
(DC output connector)
(AC input connector)
( capacitor)
(back view)
Product Information
Features :
- 4*2 miniature size
- Universal AC input / Full range
- Low leakage current <100uA
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Medical safety approved (2*MOPP between primary to sencondary)(Note.9)
- No load power consumption<0.75W
- Fixed switch frequency at 100KHz
- 3 years warranty
MODEL | RPS-60-12 | |
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 5A | |
CURRENT RANGE | 0~5A | |
RATED POWER | 60W | |
PEAK LOAD(10sec.) Note.4 | 66W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p
| |
VOLTAGE ADJ. RANGE |
11.4 ~13.2V
| |
VOLTAGE TOLERANCE Note.3 | +/-2.0% | |
LINE REGULATION | +/-0.5% | |
LOAD REGULATION | +/-1.0% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms/230VAC 13ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90~ 264VAC 127~ 370VDC (Withstand 300VAC surge for 5sec. Without damage) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 83% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 60A/230VAC 30A/115VAC | |
LEAKAGE CURRENT Note.8 | Earth leakage current < 150μA/264VAC , Touch current < 100μA/264VAC | |
OTHERS | MTBF | 353.6K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 101.6*50.8*29mm (L*W*H) | |
PACKING | 0.15Kg; 96pcs/15.4Kg/0.89CUFT |