16kw-1600kw Diesel Generator with Cummins Engine
1kw--2000kw Customized Generator Photos:
440KW Main Technical Data Reference:
GENERATOR SET | |
Genset Model | ZDE-440ST3 |
Prime Power (KVA/KW) | 550/440 |
Standby Power (KVA/KW) | 600/480 |
Frequency & Voltage | 400/230V, 50HZ |
Number of Phase | 3 |
Genset Type | Open |
Reference Dimension & Weight (W*H, mm)/KGS | 3800*1220*1900, 4000 KGS |
DIESEL ENGINE | |
Engine Brand & Model | Cummins KTAA19-G5 |
Rated Output | 440 KW |
Rated Speed | 1500RPM |
Engine Type | Four stork, in-line water cooled |
Number of Cylinder | 6 |
Bore * Stroke | 105*125mm |
Aspiration Method | Trubocharged |
Governor | Electronic speed governor |
Starting Method | Electric starting |
Cooling Method | Forced water cooled |
Lubrication Method | Pressure & splash lubricating |
Fuel Consumption | 110.2 L/H |
ALTERNATOR | |
Alternator Brand & Model | Stamford/Leroy Somer & PI 144D |
Type | Brushless & self-excited |
Number of Phase | 3 |
Volatage | 400/230V |
Frequency | 50HZ |
Power Factor | 0.8 |
Insulation Grade | H |
Protection Grade | IP22/23 |
Altitude | ≤1000m |
You may also like these gensets:
Cummins / Stamford Genset Features:
1. Engine: Cummins industrial diesel engine
2. Heat Dissipation: Radiator 40°C max, fans are driven by belt, with safe guard
3. Protective Operation: Choice of manual/auto and AMF control panels and protection systems
4. Control Panel: Digital auto-start LED panel
5. Shakeproof: Anti Vibration Suspension Absorber
6. Safe Filter: Dry type air filter, fuel filter, oil filter
7. Breaker: Mould case circuit breaker
8. Power: 24V DC start motor and storage battery
9. Nozzle: Ripple flex exhaust pipe, exhaust siphon, flange, and muffler
Product Packages:
Our bussiness partners:
CE Certifications:
Generators Use Conditions:
1. Operators need to be familiar with the operation of generating sets, operating methods, and all control bodies, manual valves, stopping body position.
2. In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1) Units exist electric shocks danger;
(2) Units exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4. Engine room or other nearest should maintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers).
5. Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6. Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7. Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dc power supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be notified stop all of this unit operation.
9. To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10. Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.