Add to Favorite | Set Home | Casual look | Mobile

Xuzhou KY Automation Technology Co.,Ltd

Company Profile

 Xuzhou KY Automation Technology Co.,Ltd

China

Main Product:ventilation resistance meter|gas detector|ultrasonic flow-meter|temperature and humidity meter|sound level meter|Laser range finder|pipeline ultrasonic leak tester

category
  • No Category
Site Search
 
link
  • No Links
Current:Home » Product Categories » » Multi-parameter Gas Detector
Similar products
Multi-parameter Gas Detector
Click to enlarge
Product:
Brand: KY 
Price: Negotiable 
MOQ:  
Total supply:
Delivery time: From the date of payment from the buyer within days of delivery
update time: 2019-04-25 11:31  Valid to:Long-term effective
  Inquiry
Profile
       Model: CD4

Description: CD4 Multi-parameter Gas Detector

MA: MFA150188 (National safety sign for coal mining products)

KA: KFA150017 (National safety sign for mining products)

ExibI : 320150860 (Intrinsic safe and explosion-proof products certificate)

ExiaII: CMExC17.4385

 

Introduction:

1. Detect the gas concentration of CH4, O2, CO, H2S.

2. 8 digitals micro-controller as control unit, high sensitivity and fast response speed, high precision detecting element.

3. Large LCD screen to ensure high definition display.

4. Detector will cause luminescence and voice alarm if gas concentration is over standard.

 

Parameters:

1. CH4:

Measuring range

Error expected

0.00~1.00

± 0.10

1.00~3.00

Truth value ± 10%

3.00~4.00

± 0.30

2. O2

Measuring range

Error expected

0.0~5.0

± 0.5

>5.0~30.0

Measuring value ± 3%

 

 

 

3. CO

                                                     Measuring range

Intrinsic error

Absolute error

Relative error

0~20

± 2

——

>20~100

± 4

——

>100~500

——

Truth value ± 4%

>500~1000

——

Truth value ± 5%

>1000~2000

——

Truth value ± 6%

4. H2S

Measuring range

Intrinsic error

0~49

± 3

50~100

Truth value ± 10%

>100~500

Truth value ± 15%

 

 

 

5. Response time: T<30s

6. Indicating method: LCD screen displays real-time data and system status.

7. Working environment: temperature -20℃~50℃

8. Humidity < 95%RH, no condensation

9. Voltage: DC3.7V

10. Recharge time: 6h~8h

11. Stand-by time: >8 hours

12. Sensor lifetime: 2 years

13. Levels of protection: IP65

14. Dimension: 68mm×33mm×124mm

15. Weight: 400g