Composite Suspension or Tension Insulator Silicone Rubber Type RL-can-*class 70kN or class 120kN
|
|
|
· Composite Suspension or Tension Insulator Silicone Rubber Type RL-can-*class 70kN or class 120kN |
|
Dimensions tolerance acc,to IEC61109 |
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
N°of Sheds A n°(1) |
Length L ±10 mm |
Leakage distance mm |
Minimnn arcing distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
12 |
17 |
24 |
36 |
45 |
66 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
|
|
|
RL-CAN-* |
2 |
366 |
295 |
166 |
65 |
55 |
100 |
110 |
1.5 |
|
|
|
|
|
|
RL-CAN-* |
3 |
407 |
435 |
207 |
75 |
60 |
130 |
140 |
1.6 |
|
|
|
|
|
|
RL-CAN-* |
4 |
540 |
540 |
248 |
85 |
70 |
160 |
170 |
1.7 |
|
|
|
|
|
|
RL-CAN-* |
5 |
680 |
680 |
289 |
100 |
85 |
180 |
200 |
1.8 |
|
|
|
|
|
|
RL-CAN-* |
6 |
785 |
785 |
330 |
110 |
100 |
200 |
230 |
1.9 |
|
|
|
|
|
|
RL-CAN-* |
7 |
571 |
925 |
336 |
120 |
110 |
220 |
250 |
2.0 |
|
|
|
|
|
|
RL-CAN-* |
8 |
612 |
1030 |
412 |
135 |
120 |
240 |
285 |
2.1 |
|
|
|
|
|
|
RL-CAN-* |
9 |
653 |
1170 |
453 |
150 |
130 |
260 |
315 |
2.2 |
|
|
|
|
|
|
RL-CAN-* |
10 |
694 |
1275 |
480 |
160 |
140 |
280 |
330 |
2.3 |
|
|
|
|
|
|
RL-CAN-* |
11 |
735 |
1415 |
535 |
175 |
155 |
305 |
355 |
2.4 |
|
|
|
|
|
|
RL-CAN-* |
12 |
1520 |
1570 |
576 |
190 |
165 |
325 |
375 |
2.5 |
|
|
|
|
|
|
RL-CAN-* |
13 |
817 |
1660 |
617 |
215 |
180 |
340 |
395 |
2.6 |
|
|
|
|
|
|
RL-CAN-* |
14 |
858 |
1765 |
658 |
230 |
200 |
370 |
430 |
2.7 |
|
|
|
|
|
|
RL-CAN-* |
15 |
899 |
1905 |
699 |
250 |
220 |
410 |
465 |
2.8 |
|
|
|
|
|
|
RL-CAN-* |
16 |
940 |
2010 |
740 |
260 |
230 |
450 |
490 |
2.9 |
|
|
|
|
|
|
RL-CAN-* |
17 |
981 |
2150 |
781 |
280 |
250 |
480 |
520 |
3.0 |
|
|
|
|
|
|
RL-CAN-* |
18 |
1022 |
2250 |
822 |
290 |
260 |
500 |
540 |
3.1 |
|
|
|
|
|
|
RL-CAN-* |
19 |
2395 |
2360 |
863 |
300 |
270 |
520 |
560 |
3.2 |
|
|
|
|
|
|
RL-CAN-* |
20 |
1104 |
2500 |
904 |
315 |
280 |
540 |
580 |
3.3 |
|
|
|
|
|
|
RL-CAN-* |
21 |
1145 |
2640 |
945 |
330 |
300 |
570 |
615 |
3.4 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
SOCKET |
BALL |
SB |
0 |
CLEVIS |
TONGUE |
CT |
+35 |
EYE |
EYE |
EE |
+64 |
EYE |
BALL |
EB |
+29 |
EYE |
TONGUE |
ET |
+27 |
CLEVIS |
BALL |
CB |
-8 |
SOCKET |
EYE |
SE |
-10 |
Y-CLEVIS |
TONGUE |
YT |
+15 |
Y-CLEVIS |
EYE |
TE |
+52 |
|
|
Specified Mechanical Load SML-IEC61109
Routine Test Load RTL=50%of SML
Specified Mechanical Load 70kN 120kN
Routing Test Load 35kN 60kN
Max.torsion Load 90N*m 90N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:RL-CAN-A(1)-120(2)
Example:RL-CAN-A7-120SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions.
|
|
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations. |
· Transmission Composite Supection-Tension Insulators in Silicone Rubber Type RL-ROK-*class 70kN or class 120kN |
|
Dimensions tolerance acc,to IEC61109 |
,
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
N°of Sheds A n°(1) |
Length L ±10 mm |
Leakage distance mm |
Minimnn arcing distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
72 |
123 |
145 |
170 |
250 |
400 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
|
|
|
RL-ROK-* |
9+8 |
915 |
2312 |
690 |
275 |
195 |
460 |
495 |
4,4 |
|
|
|
|
|
|
RL-ROK-* |
10+9 |
1010 |
2584 |
756 |
310 |
230 |
515 |
550 |
4,9 |
|
|
|
|
|
|
RL-ROK-* |
12+11 |
1160 |
3128 |
915 |
340 |
265 |
570 |
615 |
5,4 |
|
|
|
|
|
|
RL-ROK-* |
14+13 |
1310 |
3672 |
1065 |
380 |
300 |
620 |
670 |
5,9 |
|
|
|
|
|
|
RL-ROK-* |
15+14 |
1385 |
3944 |
1140 |
415 |
335 |
670 |
725 |
6,4 |
|
|
|
|
|
|
RL-ROK-* |
17+16 |
1535 |
4488 |
1290 |
450 |
370 |
720 |
780 |
6,9 |
|
|
|
|
|
|
RL-ROK-* |
19+18 |
1685 |
502 |
1440 |
485 |
405 |
770 |
835 |
7,4 |
|
|
|
|
|
|
RL-ROK-* |
21+20 |
1835 |
5576 |
1590 |
520 |
435 |
830 |
900 |
7,9 |
|
|
|
|
|
|
RL-ROK-* |
22+21 |
1910 |
5848 |
1665 |
565 |
475 |
915 |
990 |
8,4 |
|
|
|
|
|
|
RL-ROK-* |
24+23 |
2060 |
6392 |
1815 |
615 |
515 |
1000 |
1080 |
8,9 |
|
|
|
|
|
|
RL-ROK-* |
26+25 |
2210 |
6936 |
1965 |
645 |
545 |
1070 |
1155 |
9,4 |
|
|
|
|
|
|
RL-ROK-* |
27+26 |
2285 |
7208 |
2040 |
675 |
575 |
1140 |
1230 |
9,7 |
|
|
|
|
|
|
RL-ROK-* |
29+28 |
2435 |
7752 |
2190 |
710 |
605 |
1210 |
1310 |
10,4 |
|
|
|
|
|
|
RL-ROK-* |
31+30 |
2585 |
8296 |
2340 |
760 |
640 |
1270 |
1370 |
10,9 |
|
|
|
|
|
|
RL-ROK-* |
33+32 |
2735 |
8840 |
2490 |
810 |
675 |
1330 |
1430 |
11,4 |
|
|
|
|
|
|
RL-ROK-* |
35+34 |
2885 |
9384 |
2640 |
860 |
710 |
1390 |
1490 |
11,9 |
|
|
|
|
|
|
RL-ROK-* |
36+35 |
2960 |
9656 |
2715 |
875 |
720 |
1450 |
1565 |
12,4 |
|
|
|
|
|
|
RL-ROK-* |
38+37 |
3110 |
10200 |
2865 |
890 |
740 |
1520 |
1640 |
12,9 |
|
|
|
|
|
|
RL-ROK-* |
40+39 |
3260 |
10744 |
3015 |
905 |
100% |
1585 |
1715 |
13,4 |
|
|
|
|
|
|
RL-ROK-* |
42+41 |
3410 |
11288 |
3165 |
920 |
760 |
1650 |
1800 |
13,9 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
SOCKET |
BALL |
SB |
0 |
CLEVIS |
TONGUE |
CT |
-40 |
EYE |
EYE |
EE |
+55 |
EYE |
BALL |
EB |
+20 |
EYE |
TONGUE |
ET |
+5 |
CLEVIS |
BALL |
CB |
-25 |
SOCKET |
EYE |
SE |
+30 |
Y-CLEVIS |
TONGUE |
YT |
+5 |
Y-CLEVIS |
EYE |
TE |
+50 |
|
|
Specified Mechanical Load SML-IEC61109
Routine Test Load RTL=50%of SML
Specified Mechanical Load 70kN 120kN
Routing Test Load 35kN 60kN
Max.torsion Load 90N*m 90N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:RL-ROK-A(1)-70(2)
Example:RL-ROK-A22+21-70SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions. |
|
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations. |
· Transmission Composite Supection-Tension Insulators in Silicone Rubber Type RL-ROK-*class 160kN or class210kN |
|
Dimensions tolerance acc,to IEC61109 |
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
N°of Sheds A n°(1) |
Length L ±10 mm |
Leakage distance mm |
Minimnn arcing distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
72 |
123 |
145 |
170 |
250 |
400 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
|
|
|
RL-ROK-* |
9+8 |
988 |
2375 |
778 |
275 |
195 |
460 |
495 |
4,4 |
|
|
|
|
|
|
RL-ROK-* |
10+9 |
1072 |
2650 |
862 |
310 |
230 |
515 |
550 |
4,9 |
|
|
|
|
|
|
RL-ROK-* |
12+11 |
1240 |
3200 |
1020 |
340 |
265 |
570 |
615 |
5,4 |
|
|
|
|
|
|
RL-ROK-* |
14+13 |
1408 |
3100% |
1198 |
380 |
300 |
620 |
670 |
5,9 |
|
|
|
|
|
|
RL-ROK-* |
15+14 |
1492 |
4025 |
1282 |
415 |
335 |
670 |
725 |
6,4 |
|
|
|
|
|
|
RL-ROK-* |
17+16 |
1660 |
4575 |
1450 |
450 |
370 |
720 |
780 |
6,9 |
|
|
|
|
|
|
RL-ROK-* |
19+18 |
1828 |
5125 |
1618 |
485 |
405 |
770 |
835 |
7,4 |
|
|
|
|
|
|
RL-ROK-* |
21+20 |
1996 |
5675 |
1786 |
520 |
435 |
830 |
900 |
7,9 |
|
|
|
|
|
|
RL-ROK-* |
22+21 |
2080 |
5950 |
1870 |
565 |
475 |
915 |
990 |
8,4 |
|
|
|
|
|
|
RL-ROK-* |
24+23 |
2248 |
6500 |
2038 |
615 |
515 |
1000 |
1080 |
8,9 |
|
|
|
|
|
|
RL-ROK-* |
26+25 |
2416 |
7050 |
2206 |
645 |
545 |
1070 |
1155 |
9,4 |
|
|
|
|
|
|
RL-ROK-* |
27+26 |
2500 |
7325 |
2274 |
675 |
575 |
1140 |
1230 |
9,7 |
|
|
|
|
|
|
RL-ROK-* |
29+28 |
2668 |
7875 |
2458 |
710 |
605 |
1210 |
1310 |
10,4 |
|
|
|
|
|
|
RL-ROK-* |
31+30 |
2836 |
8425 |
2626 |
760 |
640 |
1270 |
1370 |
10,9 |
|
|
|
|
|
|
RL-ROK-* |
33+32 |
3004 |
8975 |
2784 |
810 |
675 |
1330 |
1430 |
11,4 |
|
|
|
|
|
|
RL-ROK-* |
35+34 |
3172 |
9525 |
2962 |
860 |
710 |
1390 |
1490 |
11,9 |
|
|
|
|
|
|
RL-ROK-* |
36+35 |
3256 |
9800 |
3046 |
875 |
720 |
1450 |
1565 |
12,4 |
|
|
|
|
|
|
RL-ROK-* |
38+37 |
3424 |
10350 |
3214 |
890 |
740 |
1520 |
1640 |
12,9 |
|
|
|
|
|
|
RL-ROK-* |
40+39 |
3592 |
10900 |
3382 |
905 |
100% |
1585 |
1715 |
13,4 |
|
|
|
|
|
|
RL-ROK-* |
42+41 |
3760 |
11450 |
3550 |
920 |
760 |
1650 |
1800 |
13,9 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
SOCKET |
BALL |
SB |
0 |
CLEVIS |
TONGUE |
CT |
-40 |
EYE |
EYE |
EE |
+55 |
EYE |
BALL |
EB |
+20 |
EYE |
TONGUE |
ET |
+5 |
CLEVIS |
BALL |
CB |
-25 |
SOCKET |
EYE |
SE |
+30 |
Y-CLEVIS |
TONGUE |
YT |
+5 |
Y-CLEVIS |
EYE |
TE |
+50 |
|
|
Specified Mechanical Load SML-IEC61109
Routine Test Load RTL=50%of SML
Specified Mechanical Load 160kN 210kN
Routing Test Load 80kN 105kN
Max.torsion Load 120N*m 120N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:RL-ROK-A(1)-(160 or 210)(2)
Example:RL-ROK-A22+21-(160 or 210)SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions. |
|
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations. |
· Transmission Composite Supection-Tension Insulators in Silicone Rubber Type RL-SOR-*class 300kN |
|
Dimensions tolerance acc,to IEC61109 |
,
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
N°of Sheds A n°(1) |
Length L ±10 mm |
Leakage distance mm |
Minimnn arcing distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
115 |
145 |
170 |
345 |
420 |
500 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
|
|
|
RL-SOR-* |
7+6+6 |
916 |
1920 |
628 |
350 |
275 |
580 |
625 |
3.6 |
|
|
|
|
|
|
RL-SOR-* |
9+8+8 |
1082 |
2560 |
844 |
3850 |
300 |
620 |
670 |
4.4 |
|
|
|
|
|
|
RL-SOR-* |
11+10+10 |
1248 |
3200 |
1010 |
415 |
335 |
670 |
725 |
5.2 |
|
|
|
|
|
|
RL-SOR-* |
13+12+12 |
1414 |
3840 |
1176 |
455 |
375 |
725 |
785 |
6.1 |
|
|
|
|
|
|
RL-SOR-* |
15+14+14 |
1580 |
4480 |
1342 |
480 |
400 |
765 |
830 |
6.9 |
|
|
|
|
|
|
RL-SOR-* |
17+16+16 |
1746 |
5120 |
1508 |
525 |
440 |
840 |
910 |
7.8 |
|
|
|
|
|
|
RL-SOR-* |
19+18+18 |
1912 |
5760 |
1674 |
570 |
480 |
920 |
995 |
8.6 |
|
|
|
|
|
|
RL-SOR-* |
21+22+22 |
2078 |
6400 |
1840 |
610 |
510 |
990 |
1070 |
9.5 |
|
|
|
|
|
|
RL-SOR-* |
23+22+22 |
2244 |
7040 |
2006 |
645 |
545 |
1050 |
1155 |
10.3 |
|
|
|
|
|
|
RL-SOR-* |
25+24+24 |
2410 |
7680 |
2172 |
685 |
585 |
1150 |
1240 |
11.1 |
|
|
|
|
|
|
RL-SOR-* |
27+26+26 |
2576 |
8320 |
2338 |
700 |
595 |
1200 |
1300 |
12.0 |
|
|
|
|
|
|
RL-SOR-* |
29+28+28 |
2742 |
8960 |
2504 |
740 |
620 |
1250 |
1350 |
12.8 |
|
|
|
|
|
|
RL-SOR-* |
31+30+30 |
2908 |
9600 |
2670 |
815 |
660 |
1340 |
1440 |
13.7 |
|
|
|
|
|
|
RL-SOR-* |
33+32+32 |
3074 |
10240 |
2836 |
845 |
685 |
1380 |
1480 |
14.5 |
|
|
|
|
|
|
RL-SOR-* |
35+34+34 |
3240 |
10880 |
3002 |
865 |
710 |
1485 |
1585 |
15.4 |
|
|
|
|
|
|
RL-SOR-* |
37+36+36 |
3406 |
11520 |
3168 |
900 |
100% |
1670 |
1820 |
16.2 |
|
|
|
|
|
|
RL-SOR-* |
39+38+38 |
3572 |
12160 |
3334 |
930 |
780 |
1760 |
1860 |
17.0 |
|
|
|
|
|
|
RL-SOR-* |
41+40+40 |
3738 |
12800 |
3500 |
960 |
820 |
1780 |
1930 |
17.9 |
|
|
|
|
|
|
RL-SOR-* |
43+42+42 |
3904 |
13440 |
3666 |
1140 |
1020 |
2030 |
2110 |
18.7 |
|
|
|
|
|
|
RL-SOR-* |
47+46+46 |
4236 |
14720 |
3998 |
1280 |
1100 |
2400 |
2510 |
19.5 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
SOCKET |
BALL |
SB |
0 |
CLEVIS |
BALL |
CT |
0 |
SOCKET |
TONGUE |
ST |
0 |
CLEVIS |
TONGUE |
CT |
0 |
|
|
Specified Mechanical Load SML-IEC61109
Routine Test Load RTL=50%of SML
Specified Mechanical Load 300kN
Routing Test Load 155kN
Max.torsion Load 200N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:RLK-SOK-A(1)-(300)(2)
Example:RL-SOK-A21+20-300SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions. |
Socket and ball are size 24 acc.To IEC60120 Clevis and tongue are size 25 Lacc.To IEC60471 |
|
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations. |
|
|
Composite Horizontal Line Post Insulator in Silicone Rubber Type RL-FC-*
|
|
|
· Composite Horizontal Line Post Insulator in Silicone Rubber Type RL-FC-* |
|
Dimensions tolerance acc,to IEC61952 |
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
Specified Cantilever Load kN |
N°of Sheds A n°(1) |
Length L ±5 mm |
Leakage distance mm |
Dry arc distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
12 |
17 |
24 |
36 |
45 |
52 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
|
|
|
RL-FC-* |
10.0 |
2+1 |
365 |
390 |
165 |
70 |
65 |
115 |
160 |
6,5 |
|
|
|
|
|
|
RL-FC-* |
8.4 |
3+2 |
420 |
585 |
225 |
110 |
100 |
150 |
190 |
7,0 |
|
|
|
|
|
|
RL-FC-* |
7.2 |
4+3 |
480 |
780 |
285 |
120 |
110 |
180 |
215 |
7,5 |
|
|
|
|
|
|
RL-FC-* |
6.3 |
5+4 |
540 |
975 |
340 |
150 |
140 |
235 |
270 |
8,0 |
|
|
|
|
|
|
RL-FC-* |
5.5 |
6+5 |
600 |
1170 |
400 |
170 |
155 |
270 |
300 |
8,5 |
|
|
|
|
|
|
RL-FC-* |
5.0 |
7+6 |
660 |
1365 |
460 |
180 |
165 |
285 |
325 |
9,0 |
|
|
|
|
|
|
RL-FC-* |
4.5 |
8+7 |
715 |
1560 |
520 |
200 |
185 |
305 |
355 |
9,5 |
|
|
|
|
|
|
RL-FC-* |
4.2 |
9+8 |
775 |
1755 |
575 |
225 |
210 |
345 |
405 |
10,0 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
Fitting GB |
Fitting HC |
HCGB |
0 |
Fitting M |
Fitting HC |
HCM |
+36 |
Fitting R |
Fitting HC |
HCR |
-78 |
Fitting GB |
Fitting B |
BGB |
+9 |
Fitting M |
Fitting B |
BM |
+44 |
Fitting R |
Fitting B |
BR |
-69 |
Fitting GB |
Fitting C |
CGB |
-40 |
Fitting M |
Fitting C |
CM |
-150 |
Fitting R |
Fitting C |
CR |
-105 |
|
|
Specified Cantilever Load SML-IEC61952
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A4+3-HCGB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions. |
|
These insulators are produced and tested according to IEC61952. It’s possible to have all the other combinations. |
· Composite Horizontal Line Post Insulator in Silicone Rubber Type RL-FC-* |
|
Dimensions tolerance acc,to IEC61952 |
Selection Guide
(Line Voltage,kv) |
Catalogue Code(◆) |
Specified Cantilever Load kN |
N°of Sheds A n°(1) |
Length L ±5 mm |
Leakage distance mm |
Dry arc distance mm |
Power frequency withstand 50Hz |
Lightning impul. withstand 1,2/50 |
Weight~kg |
72 |
115 |
150 |
Dry
kV |
Wet
kV |
posit kV |
negat
.kV |
|
|
|
RL-FC-* |
3,9 |
10+9 |
840 |
1950 |
635 |
270 |
225 |
450 |
490 |
10,5 |
|
|
|
RL-FC-* |
3,3 |
12+11 |
955 |
2340 |
100% |
310 |
245 |
515 |
550 |
11,5 |
|
|
|
RL-FC-* |
3,0 |
14+13 |
1070 |
2730 |
870 |
355 |
285 |
570 |
615 |
12,5 |
|
|
|
RL-FC-* |
2,7 |
16+15 |
1185 |
3120 |
985 |
400 |
320 |
625 |
670 |
13,5 |
|
|
|
RL-FC-* |
2,4 |
18+17 |
1300 |
3510 |
1105 |
435 |
355 |
680 |
735 |
14,5 |
|
|
|
RL-FC-* |
2,2 |
20+19 |
1415 |
3900 |
1220 |
475 |
390 |
100% |
805 |
15,5 |
|
|
|
RL-FC-* |
2,0 |
22+21 |
1525 |
4290 |
1335 |
520 |
430 |
820 |
890 |
16,5 |
|
|
|
RL-FC-* |
1,8 |
24+23 |
1640 |
4680 |
1455 |
560 |
475 |
870 |
940 |
17,5 |
|
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please selec the kind of fitting end you have to use and refer to the following table: |
Ground fitting |
Line fitting |
Code(2) |
Length
change(L) |
Fitting GB |
Fitting HC |
HCGB |
0 |
Fitting M |
Fitting HC |
HCM |
+36 |
Fitting R |
Fitting HC |
HCR |
-78 |
Fitting GB |
Fitting B |
BGB |
+9 |
Fitting M |
Fitting B |
BM |
+44 |
Fitting R |
Fitting B |
BR |
-69 |
Fitting GB |
Fitting C |
CGB |
-40 |
Fitting M |
Fitting C |
CM |
-150 |
Fitting R |
Fitting C |
CR |
-105 |
|
|
Specified Cantilever Load SML-IEC61952
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A16+15-HCGB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions. |
|
These insulators are produced and tested according to IEC61952. It’s possible to have all the other combinations. |
|
|
|