Measurement: SO2, NO, CO, CO2, O2
Technology: SO2, NO, CO, CO2 (Micro-flow NDIR)
O2 (Electrochemical)
Range: SO2: 0-2000ppm
NO: 0-2000ppm
CO: 0-5000ppm
CO2: 0-25%
O2: 0-25%
Resolution: SO2, NO, CO: 1ppm
CO2, O2: 0.01%
Precision: SO2, NO, CO, CO2 ≤2%FS
O2 ≤3%FS
Repeatability: SO2, NO, CO, CO2, O2 ≤2%FS
Flow: 0.7-1.2 L/min
Inlet pressure: 2kPa-50kPa
Sampling gas condition: no water vapor, no dust .
Response time (T90): <10s (NDIR)
Other parameters(optional):gas temperature,gas pressure,gas velocity,ambient temperature and ambient pressure
Gas analyzer features:
1.Innovative micro-flow NDIR technology.
2.Measure SO2, NO,CO,CO2,O2 and optional temperature, pressure and flow.
3.Less interference of H2O for SO2 and NO measurement.
4.Built-in zero pump and auto zero calibration with fresh air.
5.Optional printer.
6.Calculation of Lambda and combustion efficiency.
7.Touch screen.
8.USB output.
Gas conditioning system features:
1.Efficient peltier dehumidifiers for humidity measurement of low concentrations. 2.PID temperature control.
3.Needle valve flow control.
4.Built-in sampling pump and peristaltic pump.
Sampling probe with heated tube features:
1.Integrate heated sampling probe and sampling hose.
2.Built-in heated filter, prevent sampling loss.
3.Max working temperature 200℃.
4.Smart design, safe and reliable.
5.Filter element: 2 um
6.Length: 3m
7.Power supply: 220V AC
8.Power consumption: 330W
9.Environmental temperature: -40℃-140℃