INTRODUCTION:
DWDM Module - Features |
|
·Low insertion loss ·Low PDL ·High channel isolation ·Excellent environmental reliability |
|
DWDM Module - Applications |
|
·WDM system ·CATV ·MAN (Metropolitan Area Network) |
|
DWDM Module can solve the shortage of fiber resources and transparent transmission of business, and reduce the cost of network Construction. With low-cost and compact dimension, it is mainly used in metropolitan area network and access layer, also be used to build networks. |
|
DWDM Module - Specifications |
Parameters |
Unit |
SUN-DWDM Module |
|||||
Wavelength Range |
|
ITU channels 186.6 to196.1 THz |
|||||
Channel Center Wavelength |
nm |
ITU channels |
|||||
Channel Spacing |
Ghz |
100 |
200 |
||||
Channel Passband (@-0.5dB) |
nm |
0.22 |
0.5 |
||||
Channel No. |
λ |
2 |
4 |
8 |
16 |
32 |
|
Insertion Loss
|
dB |
≤ 1.4 |
≤ 2.0 |
≤ 2.8 |
≤4.5 |
≤ 5.5 |
|
Adjacent Channel Isolation |
dB |
≥ 30 |
|||||
Non-adjacent Channel Isolation |
dB |
≥ 45 |
|||||
Wavelength thermal stability |
nm/℃ |
≤ 0.003 |
|||||
Insertion loss thermal stability |
dB/℃ |
≤ 0.005 |
≤ 0.007 |
≤ 0.008 |
|||
PDL |
dB |
≤ 0.1 |
≤ 0.15 |
≤ 0.15 |
≤ 0.20 |
≤ 0.25 |
|
Polarization mode dispersion |
ps |
≤ 0.1 |
≤ 0.15 |
||||
Directivity |
dB |
≥ 50 |
|||||
Return loss |
dB |
≥ 45 |
|||||
Optical Power |
mW |
≤ 500 |
|||||
Operating Temperature |
℃ |
-10 ~ +70 |
|||||
Storage Temperature |
℃ |
-40 ~ +85 |
|||||
Relative Humidity |
% |
5 ~ 95 |
|||||
Dimension |
mm |
ABS Box or LGX Box or 1U(2U) Rackmount |
Note: 1. Customization is available. 2. Specified without connector, and add an additional 0.2dB loss per connector. DWDM Module - Dimension |
1081: 100×80×10.5 mm 1411: 140×115×18 mm 1U LGX |
DWDM Module - Optical path connection diagram |
DWDM Module - Ordering Information: SUN-DWDM-A-B-C-D-E-F |
A |
B |
C |
D |
E |
F |
Channel No. |
Tube Type |
Fiber Length |
Connector |
Dimension |
Channel Number Detail
|
8: 8 channels |
25:250um
|
05: 0.5m±0.05m |
OO:None |
1081: 100×80×10.5mm |
CH21 / CH22 / CH23 /... |